User manual

6. Door Staon Configuraons
-7--6-
1. About room code(address):
Room Code(also called room address) is a code assigned to each monitor, to idenfy
different monitors; each monitor have a unique room code in one buidling.The room
Code is stored in each Monitor’s inner EEPROM memory, and does not lose even the
monitor is power off.
2. About Debug State:
The Debug State is your starng point for using all the applicaons on DMR18.
3. About Debug Tools:
During working at Debug State,press "1#" to enter tools page,Debug Tools overviews is
shown as below:
2. External Power Supply Mode
C. Connecon for Power-to-Unlock type:
D. Connecon for Power--off-to-Unlock type:
When the electronic lock is over 12 Vdc, addional power supply for the lock is needed.
• The power supply for the lock must be less than 48Vdc 1.5A.
• The Jumper must be removed when using external power supply. The default seng
is Power-on-to-Unlock type(Normally open mode), if use Power-off-to-Unlock type,
change the Unlock Relay mode to Normally closed mode .
• If different unlocking me is needed to be configured, change the Unlock Timing on
door staon. (In debug state, press [1 #] --> [1] Installer Setup--> [2]Unlock Timing)
1. Installer Setup
2. Setup
3. Card Memory
4. Online Monitors
5. Online Devices
6. Voltage Measure
*Back
Tools
>> Debug State <<
2-# Exits
1-# Tools
Pres NO.
to select
+
+
-
-
+12V
LK - (GND)
LK+(COM)
N.O.
EB+
EB -
Remove the Jumper
set to Normally Open on the
Unlock Relay mode (default)
JP_LK
1
2
3
Note: Cut off this line when
using external power supply
+12V
LK - (GND)
LK+(COM)
N.O.
EB+
EB -
Remove the Jumper
set to Normally Closed on the
Unlock Relay mode
+
+
-
-
JP_LK
1
2
3
Note: Cut off this line when
using external power supply
[ 9 0 0 8 ]
Please Input Password
>> Debug State <<
1-# Tools
0-# Redial
2-# Exits
1 2 3
654
7 8 9
#0
*
When Door Staon is in
standby, press '#' key
input '9008', then input the
Admin Code.(66666666 by
default)
Debug State menu is launched
Press "2#" key to exit out the debug state.