User manual
monitor
intercom
setup
exit
Outdoor Tone -- 01
Intercom Tone -- 05
Monitor Time -- 1min
Advanced Set...
Auto Record -- OFF
Exit
0
* * *
Password:
Slave Addr Set -- 0
Guard Unit Set -- 0
Date/Time Set...
Other Settings...
Information...
Exit
Hardware ver 0302
Software ver 0168
Voltage 22.4V
Manufacture 00.0T
Restore to default
Exit
Unlock Time 1
Unlock Mode 0
Exit
1. Press
setup
setup item
on main menu page.
2. Select Advanced Set...
password is required.
4. Select Informaon... 5. Press UNLOCK buon
and hold for 2s.
6. Set unlock mode to
0 or 1.
3. The default password is
2008.
4.3 Electromagnec Lock Connecon
Note:
1. Only applicable to the power off to unlock type of electronic locks.
2. The door lock is limited to 12V, and holding current must be less than 250mA.
3. The door lock control is not med from Exit Buon(EB).
4. The Unlock Mode Parameter of Monitor must be set to 1 (by default).
4.3.1 Door Lock Controlled by Internal Power
Connect one lock
Jumper posion in 1-2
1 2 3
EB
*
LOCK
BUS PL S1+ S2+ S-
Normally closed
Connect two lock
Jumper posion in 1-2
EB
*
LOCK
LOCK
2
nd
1
ST
2
nd
EB
*
1
ST
1 2 3
BUS PL S1+ S2+ S-
Note:
1. The external power supply must be used according to the lock.
2. The inside relay contact is restricted to AC or DC 24V/3A.
3. The jumper must be taken off before connecng.
4. Setup the Unlock Mode of Monitor for different lock types.
• Power-on-to-unlock type:Unlock Mode=0 (by default)
• Power-off-to-unlock type:Unlock Mode=1
4.3.2 Door Lock Controlled by Dry Contact
Connect two lock
Take off the Jumper
1 2 3
BUS PL S1+ S2+ S-
LOCK
LOCK
POWER
SUPPLY
LOCK
BUS PL S1+ S2+ S-
POWER
SUPPLY
Connect one lock
Take off the Jumper
1 2 3
-7--6-
4.3.3 Unlock parameter seng(set in monitor)
Note:
1. Must connect DT596 correctly before seng.
2. The parameter will be saved in DT596 automacally,so you only need to set on one monitor.
3. The above cutline is fit for T107 series monitors only,for T753,T863 series monitors,please refer to the
corresponding user manuals.