Connect two lock
Jumper posion in 2-3
-4- -5-
4. System Wiring and Connecons
3. Terminal Descripons
MIC adjustment
SPK adjustment
1 2 3 4
ON DIP
Lock Control Jumper
Doorstaon Code DIP
3 2 1
BUS
PL
S1+
S2+
S-
Main Connect Port
• Lock Control Jumper: To select the lock type: see secon 5
• Doorstaon Code DIP: It supports total 4 door staons,see secon 6
• MIC: Adjust the volume of Microphone
• SPK: Adjust the volume of Speaker
• Main Connect Port: To connect the bus line and the electronic locks.
• BUS: Connect to the bus line, no polarity.
• PL: External lock power input, connect to the power posive(power +).
• S1+, S2+: Lock power(+) output, to connect 2 locks.
• S-: Lock power(-) output, connect to the power(-) input of locks(only when using the camera to power the
locks, if using the external power supply for the locks, the S- should not be connected).
4.1 Basic Connecon
4.2 Electric Lock Connecon
-
+
AC~
Monitor
DPS PS4
L1 L2 PL S1+ S2+ S-
EB
*
LOCK
BUS PL S1+ S2+ S-
LOCK
2
nd
1
ST
2
nd
EB
*
1
ST
1 2 3
EB
*
LOCK
BUS PL S1+ S2+ S-
Connect one lock
Jumper posion in 2-3
1 2 3
Note:
1. Only applicable to the power on to unlock type of electronic locks.
2. The door lock is limited to 12V, and holding current must be less than 250mA.
3. The door lock control is not med from Exit Buon(EB).
4. The Unlock Mode Parameter of Monitor must be set to 0 (by default).
4.2.1 Door Lock Controlled by Internal Power