User manual

- The user code group 1 is used to release the first lock, and the
user code group 2 is used to release the second lock.
- The user code group 1 and user code group 2 can contain 40
group passwords.
- If the password length exceeds 12 digits, the system will gove out
the sound of “beep,beep,beep,beep”, and the digits you input
before will be cleared at the same me.
- The user code can not be set the same as the master code and
temporary code.
-17--16-
• During calling,pressing "cancel" buon can cancel the call.
• If input the incorrect access code,the buzzer will give out of beep,beep,beep.a
Input the master code.
(Default : [
1 2 3 4
] +[#] )
(RED)
ON
(BLUE)
OFF
Beep + , Beep
14. Seng the code
for user group 1
15. Seng the code
for user group 2
13. Seng the code
for Temporary 2
12. Seng the code
for Temporary 1
Input the seng code.
18+#
(RED)
ON
(BLUE)
ON
Beep + , Beep
(RED)
ON
(BLUE)
OFF
Beep +
(RED)
ON
(BLUE)
OFF
Beep +
- When input the correct temporary password to release the door,
the system will clear the temporary password aer 60 seconds
automacally. But you should know that the password is valid
within 60 seconds aer inpung the correct temporary password
- The temporary 1 is used to release the first lock, and the
temporary 2 is used to release the second lock.
- If the password length exceeds 12 digits, the system will give
outof “beep,beep,beep,beep”, and the digits you input be fore will
be cleared at the same me.
- The temporary code can not be set the same as the master code
and user code.
Inpung of code
(ex.: 1006) 1~12 digits
1006 +#
Inpung of code
(ex.: 2011) 1~12 digits
2011 +#
(RED)
ON
(BLUE)
OFF
Beep +
(RED)
OFF
(BLUE)
OFF
Beep + , Beep
(RED)
ON
(BLUE)
OFF
Beep +
Input the seng code.
19+#
(RED)
ON
(BLUE)
ON
Beep + , Beep
Input the seng code.
(ex.:21)
21+#
(RED)
ON
(BLUE)
ON
Beep + , Beep
Input the seng code.
(ex.:60)
60+#
(RED)
ON
(BLUE)
ON
Beep + , Beep
- When the “ * cancel” key is pressed, the LED lights off, the buzzer beeps, and the system exits the seng mode
- When there isn’t any operaon in 10s, the LED lights off, the buzzer beeps, and the system exits the seng mode
Inpung of code
(ex.: 2011) 1~12 digits
2011 +#
Inpung of code
(ex.: 2012) 1~12 digits
2012 +#
When the registered user code has been input using the keypad (1~12 digits), the LED indicator
(group 1: red, group 2: blue) lights up, the buzzer sounds,and the electric door strike is unlocked.
• The me interval during which the buon must be pressed is approximately 10 seconds.
If the me interval exceeds approximately 10 seconds, the input code will be cleared.
If you make a mistake when inpung the user code, press the" cancel" buon and input the user code again.
• When the "Lockout" funcon is being acvated, the release funcon is forbidden and the input
operaon is disabled for 60 seconds at the 10 connnous incorrect access codes are aemt.
( "Lockout" funcon: When "Lockout" is acvated, the relay 2 doesn't respond the second lock but
responds to the LOCKOUT funcon. Aer connuously inpung incorrect access code for 10 mes,
LOCKOUT output and the relay 2 will be closed for 60 seconds, the LED-relay 2 will be illuminated for 60
seconds) During this me,the buzzer will connuously sound for about 8 mes.
• You can acvate the electric door strike by pressing the request to exit buon connected to the unit.
Pressing request to exit buon 1 releases relay 1, and pressing request to exit buon 2 releases relay 2.
(The unlock funcon will work when the request to exit buon is pushed, even while the "Lockout"
funcon is operang.)
7. Unlock Operaons
7.1 Unlocking user code
(RED)
ON
(BLUE)
OFF
Beep +
Red LED lights up
(During relay 1 operaon)
Example : Group 1
2011
(RED)
OFF
(BLUE)
ON
Beep +
Red LED lights up
(During relay 2 operaon)
Example : Group 2
2012