User manual
- The user code group 1 is used to release the first lock, and the
user code group 2 is used to release the second lock.
- The user code group 1 and user code group 2 can contain 40
group passwords.
- If the password length exceeds 12 digits, the system will gove out
the sound of “beep,beep,beep,beep”, and the digits you input
before will be cleared at the same me.
- The user code can not be set the same as the master code and
temporary code.
-17--16-
• During calling,pressing "cancel" buon can cancel the call.
• If input the incorrect access code,the buzzer will give out of beep,beep,beep.a
Input the master code.
(Default : [
1 2 3 4
] +[#] )
(RED)
ON
(BLUE)
OFF
Beep + , Beep
14. Seng the code
for user group 1
15. Seng the code
for user group 2
13. Seng the code
for Temporary 2
12. Seng the code
for Temporary 1
Input the seng code.
18+#
(RED)
ON
(BLUE)
ON
Beep + , Beep
(RED)
ON
(BLUE)
OFF
Beep +
(RED)
ON
(BLUE)
OFF
Beep +
- When input the correct temporary password to release the door,
the system will clear the temporary password aer 60 seconds
automacally. But you should know that the password is valid
within 60 seconds aer inpung the correct temporary password
- The temporary 1 is used to release the first lock, and the
temporary 2 is used to release the second lock.
- If the password length exceeds 12 digits, the system will give
outof “beep,beep,beep,beep”, and the digits you input be fore will
be cleared at the same me.
- The temporary code can not be set the same as the master code
and user code.
Inpung of code
(ex.: 1006) 1~12 digits
1006 +#
Inpung of code
(ex.: 2011) 1~12 digits
2011 +#
(RED)
ON
(BLUE)
OFF
Beep +
(RED)
OFF
(BLUE)
OFF
Beep + , Beep
(RED)
ON
(BLUE)
OFF
Beep +
Input the seng code.
19+#
(RED)
ON
(BLUE)
ON
Beep + , Beep
Input the seng code.
(ex.:21)
21+#
(RED)
ON
(BLUE)
ON
Beep + , Beep
Input the seng code.
(ex.:60)
60+#
(RED)
ON
(BLUE)
ON
Beep + , Beep
- When the “ * cancel” key is pressed, the LED lights off, the buzzer beeps, and the system exits the seng mode
- When there isn’t any operaon in 10s, the LED lights off, the buzzer beeps, and the system exits the seng mode
Inpung of code
(ex.: 2011) 1~12 digits
2011 +#
Inpung of code
(ex.: 2012) 1~12 digits
2012 +#
When the registered user code has been input using the keypad (1~12 digits), the LED indicator
(group 1: red, group 2: blue) lights up, the buzzer sounds,and the electric door strike is unlocked.
• The me interval during which the buon must be pressed is approximately 10 seconds.
If the me interval exceeds approximately 10 seconds, the input code will be cleared.
• If you make a mistake when inpung the user code, press the" cancel" buon and input the user code again.
• When the "Lockout" funcon is being acvated, the release funcon is forbidden and the input
operaon is disabled for 60 seconds at the 10 connnous incorrect access codes are aemt.
( "Lockout" funcon: When "Lockout" is acvated, the relay 2 doesn't respond the second lock but
responds to the LOCKOUT funcon. Aer connuously inpung incorrect access code for 10 mes,
LOCKOUT output and the relay 2 will be closed for 60 seconds, the LED-relay 2 will be illuminated for 60
seconds) During this me,the buzzer will connuously sound for about 8 mes.
• You can acvate the electric door strike by pressing the request to exit buon connected to the unit.
Pressing request to exit buon 1 releases relay 1, and pressing request to exit buon 2 releases relay 2.
(The unlock funcon will work when the request to exit buon is pushed, even while the "Lockout"
funcon is operang.)
7. Unlock Operaons
7.1 Unlocking user code
(RED)
ON
(BLUE)
OFF
Beep +
Red LED lights up
(During relay 1 operaon)
Example : Group 1
2011
(RED)
OFF
(BLUE)
ON
Beep +
Red LED lights up
(During relay 2 operaon)
Example : Group 2
2012