User's Manual
Table Of Contents
- Cover
- Contents
- 1 Welcome to the Card Personalization System
- 2 Installation Requirements
- 3 Install the System
- 4 Using the System
- 5 Card Design
- 6 System Maintenance
- 7 Troubleshooting
- Tools for Troubleshooting
- Locating the Issue
- Installation Troubleshooting
- Card Appearance
- Magnetic Stripe
- Card Jam
- Messages and Conditions
- Respond to Messages
- Printer Component Messages (100-124)
- 100: Request not supported
- 101: Job could not complete
- 102: Card not in position
- 103: Printer problem
- 104: Critical problem
- 105: Magstripe data error
- 106: Magstripe data not found
- 107: Magstripe read data error
- 108: Magstripe read no data
- 111: Card not picked
- 112: Hopper Empty
- 113: Close cover to continue
- 114: Cover opened during job
- 116: Magstripe not available
- 117: Reader not available
- 120: User paused the printer
- 122: Magnetic stripe format problem
- 123: Insert new card then continue
- 124: Insert same card then continue
- Embosser Component Messages (125-151)
- 125: Emboss critical issue
- 126: Emboss format issue
- 127: Emboss transport error
- 128: Embosser card jam
- 129: Embosser topper jam
- 130: Embosser card entry jam
- 131: Embosser card exit jam
- 132: Embosser card stack full
- 133: Embosser card reject full
- 135: Indent ribbon supplies out
- 136: Indent ribbon break
- 137: Embosser wheel error
- 138: Embosser indent error
- 139: Lost card, open emboss cover
- 140: Embosser not available
- 141: Close emboss cover
- 142: Emboss cover error
- 143: Topper ribbon problem
- 144: Topper ribbon out
- 145: Topper ribbon type problem
- 146: Topper ribbon support err.
- 147: Topper ribbon no tag found
- 149: Option not installed
- Printer Component Messages (100-124)
- 8 Supplies and Parts
- 9 Legal Notices
CE870 Card Personalization System Installation and User Guide 55
ABA (American Bankers Association)
The maximum number of characters for ABA format is 37 characters. Numeric
characters and the following special characters are allowed:
: ; < = >
TTS (Thrift Third Standard)
The maximum number of characters for TTS format is 104 characters. Numeric
characters and the following special characters are allowed:
: ; < = >
Single-Track JIS Option
The default data encoding format for a single-track magnetic stripe module is the
JIS (Japanese Industrial Standard) Type II format.
The maximum number of characters for the JIS format is 69 characters. These
characters can include spaces, numeric characters, upper case alphabetic
characters, lower case alphabetic characters, and the following special characters:
! " # $ % & ' ( ) * + , - . / : ; < = > ? @ [ ] ^ _ ~ { | } ~
From a PC running a Japanese edition of a supported operating system Japanese-
language characters are also supported. They include the following special
characters:
45 Katakana characters: