User's Manual
Table Of Contents
- Cover
- Contents
- 1 Welcome to the Card Personalization System
- 2 Installation Requirements
- 3 Install the System
- 4 Using the System
- 5 Card Design
- 6 System Maintenance
- 7 Troubleshooting
- Tools for Troubleshooting
- Locating the Issue
- Installation Troubleshooting
- Card Appearance
- Magnetic Stripe
- Card Jam
- Messages and Conditions
- Respond to Messages
- Printer Component Messages (100-124)
- 100: Request not supported
- 101: Job could not complete
- 102: Card not in position
- 103: Printer problem
- 104: Critical problem
- 105: Magstripe data error
- 106: Magstripe data not found
- 107: Magstripe read data error
- 108: Magstripe read no data
- 111: Card not picked
- 112: Hopper Empty
- 113: Close cover to continue
- 114: Cover opened during job
- 116: Magstripe not available
- 117: Reader not available
- 120: User paused the printer
- 122: Magnetic stripe format problem
- 123: Insert new card then continue
- 124: Insert same card then continue
- Embosser Component Messages (125-151)
- 125: Emboss critical issue
- 126: Emboss format issue
- 127: Emboss transport error
- 128: Embosser card jam
- 129: Embosser topper jam
- 130: Embosser card entry jam
- 131: Embosser card exit jam
- 132: Embosser card stack full
- 133: Embosser card reject full
- 135: Indent ribbon supplies out
- 136: Indent ribbon break
- 137: Embosser wheel error
- 138: Embosser indent error
- 139: Lost card, open emboss cover
- 140: Embosser not available
- 141: Close emboss cover
- 142: Emboss cover error
- 143: Topper ribbon problem
- 144: Topper ribbon out
- 145: Topper ribbon type problem
- 146: Topper ribbon support err.
- 147: Topper ribbon no tag found
- 149: Option not installed
- Printer Component Messages (100-124)
- 8 Supplies and Parts
- 9 Legal Notices
14 Installation Requirements
Site Requirements
Set up and use the system in an environment that meets the following
requirements.
• It is recommended that the system be placed on a table that is no taller than 32
inches (81 cm) in height to allow easy user access and viewing of components.
• Provide space for the system and for clearance around the system. The system
dimensions and recommended clearance area are shown in the table below.
• Choose a location in an environment with temperatures ranging from
60° to 95° F (15° to 35° C).
• Use single phase, 3-wire, grounded receptacles.
• Keep all dust, dirt, food, and liquids away from the system.
• Place the system and its supplies in a clean office environment, keeping paper
and foreign materials off the equipment.
Dimensions (in/cm)
ABCDEFGXY
in 27.6 2 16.3 8.5 10 28.1 2 26.8 40.1
cm 70.1 5.1 41.4 21.6 25.4 71.4 5.1 68.1 101.9