Operation Manual

59
IP2162EN - 2014-04-17
5. Outputs and accessories
Output
Value
Accessories
Description
0
-
1
+
24 V 0.3 A
Accessories power supply.
External accessories power supply output.
N.B.: the maximum absorption of 0.3 A corresponds to the
sum of all terminals 1.
GOL148REA
(433, 92 MHz)
Antenna connection (433, 92 MHz).
If the inside radio receiver is used, connect the supplied antenna
wire (173 mm), or alternatively the GOL148REA antenna, using a
coaxial cable, type RG58.
+LP-
LAMPH
24 V
25 W
Flashing light.
The pre-ashing settings can be selected from the third level
menu
and/or .
AUX
The control panel has a housing for plug-in cards.
The action of the card can be selected by selecting
.
WARNING: the plug-in cards must be inserted and removed
with the power supply disconnected.
COM
BIXMR2
This allows the functioning configurations to be saved using
the function .
The saved congurations can be recalled using the function
.
The storage module allows the remote controls to be stored.
If the control panel is replaced, the storage module being
used can be inserted in the new control panel.
WARNING: the storage module must be inserted and re-
moved with the power supply disconnected.
LSW
NES100FCM
Magnetic limit switch kit (optional only for Ditec NES300 -
NES400).
BAT
NES100BBU
2x12 V 2Ah
BAT - Batteries functioning.
The batteries are kept charged when the power supply is on. If
the power supply is off, the panel is powered by the batteries
until the power is re-establish or until the battery voltage drops
below the safety threshold. The panel turns off in the last case.
WARNING: the batteries must always be connected to the
control panel for charging. Periodically check the efficiency of
the batteries.
N.B.: the operating temperature of the rechargeable batteries is
approximately +5°C/+40°C.
Mains power supply, motor, release microswitch and automa-
tion wiring connection.