Operation Manual

67
IP2162EN - 2014-04-17
ǩ XVLQJNH\VǴDQGǶVHOHFWWKHGHVLUHGIXQFWLRQ
ǩ SUHVVWKH(17(5NH\WRFRQȌUP
7.6 Second level menu - BA (Basic Adjustment)
Display Description
MT - Display of type of automation.
N3 - Motor with 300 kg capacity
N4 - Motor with 400 kg capacity
N6 - Motor with 600 kg capacity
N.B.: this parameter is DISPLAY only.
TC - Setting of automatic closing time. [s]
It is set with different intervals of sensitivity.
ǩ from 0” to 59” with intervals of 1 second;
ǩ from 1’ to 2’ with intervals of 10 seconds.
1’00
RP - Adjustment of partial opening measurement.
[%]
Adjusts the percentage of operation in relation to the
total opening of the automation.
10 - Minimum
99 - Maximum
30
TP - Setting of automatic closing time after partial
opening. [s]
It is set with different intervals of sensitivity.
ǩ from 0” to 59” with intervals of 1 second;
ǩ from 1’ to 2’ with intervals of 10 seconds.
00’30’’
VA - Setting of opening speed. [cm/s]
N.B.:
24 - Maximum with
25 - Maximum with or
15
VC - Setting of closing speed. [cm/s]
N.B.:
24 - Maximum with
25 - Maximum with or
15