Operation Manual

63
IP2162EN - 2014-04-17
ǩ XVLQJNH\VǴDQGǶVHOHFWWKHGHVLUHGIXQFWLRQ
ǩ SUHVVWKH(17(5NH\WRFRQȌUP
7.4 Second level menu
AT (Automatic Configurations)
Display Description
RT - Opening to right.
LF - Opening to left.
H0 - Predefined setting, residential use 0.
This selection loads predefined values for certain standard parameters:
AC - enabling of automatic closing : disabled
C5 - step-by-step/opening command operation : step-by-step
RM - remote control operation : step-by-step
AM - AUX plug-in card operation : step-by-step
SS - Selection of automation status at start-up : open
H1 - Predened setting, residential use 1.
This selection loads predefined values for certain standard parameters:
AC - enabling of automatic closing : enabled
TC - setting of automatic closing time : 1 minute
C5 - step-by-step/opening command operation : step-by-step
RM - remote control operation : step-by-step
AM - AUX plug-in card operation : step-by-step
SS - Selection of automation status at start-up : closed
C0 - Predefined setting, condominium use 0.
This selection loads predefined values for certain standard parameters:
AC - enabling of automatic closing : enabled
TC - setting of automatic closing time : 1 minute
C5 - step-by-step/opening command operation : opening
RM - remote control operation : opening
AM - AUX plug-in card operation : opening
SS - Selection of automation status at start-up : closed
RD - Resetting of general settings (SETTINGS RESET).
2”