Ditec CS12E IP2162EN Control panel installation manual for Ditec NEOS automations JR1 COM JR3 1 5 Flashing light +LP- AUX UP NES100FCM DOWN LSW NES100BBU BAT ENTER blue ESC 24V MOTOR black Selection of automation type (FACTORY SET) + Power supply grey 0 1 6 8 Step-by-step max 0,3 A PLUG-IN CARD + Safety stop Closing safety device Output 24 V STORAGE MODULE Antenna Release microswitch www.ditecentrematic.
52 IP2162EN - 2014-04-17
Index Subject Page 1. General safety precautions 2. EC Declaration of Conformity 55 3. Technical specifications 55 4. 54 Commands 56 4.1 Inserting plug-in card (AUX) 57 4.2 Self-controlled safety edge 57 5. Outputs and accessories 59 6. Selections 60 7. Settings 60 7.1 Switching on and off 61 7.2 Key combinations 61 7.3 Main menu 62 7.4 Second level menu - AT (Automatic Configurations) 63 7.5 Second level menu - BC (Basic Configurations) 65 7.
1. General safety precautions “Important instructions for installation safety. Incorrect installation can cause serious injury” This installation manual is intended for qualified personnel only. Installation, electrical connections and adjustments must be performed in accordance with Good Working Methods and in compliance with the present standards. Read the instructions carefully before installing the product. Bad installation could be dangerous. The packaging materials (plastic, polystyrene, etc.
2. EC Declaration of Conformity The manufacturer Entrematic Group AB, with headquarters in Lodjursgatan 10, SE-261 44 Landskrona, Sweden, declares that the Ditec CS12E type control panel complies with the conditions of the following EC directives: EMC Directive 2004/108/EC Low Voltage Directive 2006/95/EC R&TTE Directive 1999/5/EC. Landskrona, 28-03-2013 Marco Zini (President & CEO) 3.
4. Commands 5 NO Function Description STEP-BY-STEP WITH AUTOMATIC CLOSING → → , closing the conWhen selecting tact starts a sequential opening or closing operation: opening-stop-closing-opening. WARNING: if automatic closing is enabled, the dura→ tion of the stop can be selected by selecting . STEP-BY-STEP WITHOUT AUTOMATIC CLOSING → → , closing the contact When selecting starts a sequential opening or closing operation: opening-stop-closing-opening.
4.1 Inserting plug-in card (AUX) To access the plug-in card (AUX), cut the control panel cover as shown in the figure. UP DOWN ENTER ESC 4.2 SOFA1-SOFA2 or GOPAVRS self-controlled safety edge Command Function IP2162EN - 2014-04-17 SOFA1-SOFA2 GOPAV Description SAFETY TEST Place the SOFA1-SOFA2 or GOPAVRS device into the special housing for AUX plug-in cards. If the test fails, an alarm message appears on the display.
Examples of installation of self-controlled safety edge JR3 0 1 6 8 AUX CS12E +LP- SOFA1-A2 1 41 IN1 IN2 OUT1 OUT2 1 5 SOFA15 SOFA20 SOFA25 SOFA15 SOFA20 SOFA25 OPENING JR3 0 1 6 8 GOPAVT CS12E AUX GOPAVRS 8K2 8K2 +LP- 1 41 IN1 IN2 OUT1 OUT2 1 5 SOFA15 SOFA20 SOFA25 IN1 IN2 +BC - OPENING IP2162EN - 2014-04-17 SOFA15 SOFA20 SOFA25 58
5. Outputs and accessories Output Value Accessories Description 24 V 0.3 A Accessories power supply. External accessories power supply output. N.B.: the maximum absorption of 0.3 A corresponds to the sum of all terminals 1. - + 0 1 GOL148REA (433, 92 MHz) +LP- LAMPH 24 V 25 W The control panel has a housing for plug-in cards. → . The action of the card can be selected by selecting WARNING: the plug-in cards must be inserted and removed with the power supply disconnected.
6. Selections Jumper 7. i 7.1 OFF ON JR1 Display mode selection. Description Display mode. Only the v alues and parameters present can be displayed. Maintenance mode. Only the v alues and parameters present can be displayed and modified. G oing into maintenance mode is indicated by the permanent switching on of the right-hand point on the display. JR3 Built-in radio receiver. Disabled. Enabled. Settings N.B.: pressure on the keys can be quick (less than 2 s) or prolonged (longer than 2 s).
7.2 Key combinations Simultaneous pressing of the keys ↑and ENTER performs an opening command. ǩ Simultaneous pressing of the keys ↓and ENTER performs a closing command. ǩ Simultaneous pressing of the keys ↑ and ↓ performs a POWER RESET command. (interruption of the power supply and restart of the automation). ǩ Keeping press the UP ↑ or DOWN ↓ key, fast menu scrolling begin. To stop menu scrolling.
7.3 Main menu ǩ XVLQJ NH\V Ǵ DQG Ƕ VHOHFW WKH GHVLUHG IXQFWLRQ ǩ SUHVV WKH (17(5 NH\ WR FRQȌUP After confirming the selection, you access the second level menu. Display Description AT - Automatic Configurations. The menu allows you to manage the automatic configurations of the control panel. BC - Basic Configurations. The menu allows you to display and modify the main settings of the control panel. BA - Basic Adjustments.
7.4 Second level menu AT (Automatic Configurations) ǩ XVLQJ NH\V Ǵ DQG Ƕ VHOHFW WKH GHVLUHG IXQFWLRQ ǩ SUHVV WKH (17(5 NH\ WR FRQȌUP Display Description RT - Opening to right. IP2162EN - 2014-04-17 LF - Opening to left. H0 - Predefined setting, residential use 0.
Display Description AA - Activating advanced parameters menu. → 2” After activation you can scroll through the third level menus. The third level menus are activated for 30 min. IP2162EN - 2014-04-17 Depending on the type of automation and control panel, some menus may not be available.
7.5 Second level menu - BC (Basic Configurations) ǩ XVLQJ NH\V Ǵ DQG Ƕ VHOHFW WKH GHVLUHG IXQFWLRQ ǩ SUHVV WKH (17(5 NH\ WR FRQȌUP Display Description AC - Enabling of automatic closing. ON - Enabled OF - Disabled SS - Selection of automation status at start. OP - Open CL - Closed Indicates how the control panel considers the automation at the time of switch-on, or after a POWER RESET command. SO - Enabling of reversal safety contact functioning.
7.5.1 Third level menu - BC (Basic Configurations) Access the third level menu by activating function Description HR - Enabling of operator present function ON - Enabled OF - Disabled N.B.: Set → only if → and → . 64 - Functioning of safety stop/closing command. 1-4 - Closing 1-6 - Safety stop C5 - Step-by-step/opening command operation. 1-5 - Step-by-step 1-3 - Opening RM - Radio receiver operation. 1-5 - Step-by-step 1-3 - Opening AM - AUX plug-in card operation.
7.6 Second level menu - BA (Basic Adjustment) ǩ XVLQJ NH\V Ǵ DQG Ƕ VHOHFW WKH GHVLUHG IXQFWLRQ ǩ SUHVV WKH (17(5 NH\ WR FRQȌUP Display Description MT - Display of type of automation. N3 - Motor with 300 kg capacity N4 - Motor with 400 kg capacity N6 - Motor with 600 kg capacity N.B.: this parameter is DISPLAY only. TC - Setting of automatic closing time. [s] It is set with different intervals of sensitivity. ǩ from 0” to 59” with intervals of 1 second; ǩ from 1’ to 2’ with intervals of 10 seconds.
Display Description R2 - Adjustment of thrust on obstacles and current during opening [%] The control panel is equipped with a safety device that stops movement if an obstacle is detected during an opening operation with disengagement of 10 cm. 00 - Minimum thrust 99 - Maximum thrust R1 - Adjustment of thrust on obstacles and current during closing [%] The control panel is fitted with a safety device which stops or reverses movement when an obstacle is detected during a closing operation.
7.6.1 Third level menu - BA (Basic Adjustment) Access the third level menu by activating function Display (see paragraph 7.4) Description DT - Adjustment of obstacle recognition time. [s/100] 10 - Minimum 60 - Maximum N.B.: the parameter is adjusted in hundredths of a second. MP - Start at maximum power ON - During start-up it increases the thrust on obstacles to maximum. OFF - During start-up the thrust on obstacles is that adjusted by ST - Adjustment of start time. [s] 0.5 - Minimum 3.
Display Description PO - Adjustment of approach speed during opening. [cm/s] Indicates the speed from the end of the deceleration ramp to the end of the stroke. 02 - Minimum 10 - Maximum N.B.: gradually increase the approach speed if there is a series of quick vibrations (chattering) in heavy gates installed with a slight incline. PC - Adjustment of approach speed during closing. [cm/s] Indicates the speed from the end of the deceleration ramp to the end of the stroke. 02 - Minimum 10 - Maximum N.B.
7.7 Second level menu - RO (Radio Operations) ǩ XVLQJ NH\V Ǵ DQG Ƕ VHOHFW WKH GHVLUHG IXQFWLRQ ǩ SUHVV WKH (17(5 NH\ WR FRQȌUP Display Description SR - Remote control storage. You can directly access the Remote control storage menu even with the display turned off, but only with the Display visualisation mode option set to 00 or 03: - for transmitting a remote control not present in the memory; - for transmitting an unstored channel of a remote control already present in the memory.
Display Description RK - Menu navigation using remote control keyboard. ON - Enabled OF - Disabled You are advised to use a NES100TXT remote control. With the display turned off, quickly type in the sequence of keys 3 3 2 4 1 from the stored remote control you want to use. Make sure all the CH keys are stored. WARNING: during navigation with a remote control keyboard ALL the stored remote controls are inactive.
7.7.1 Third level menu - RO (Radio Operations) Access the third level menu by activating function Display (see paragraph 7.4) Description C1, C2, C3, C4 - Selection of CH1, CH2, CH3, CH4 function of stored remote control. NO - No setting selected 1-3 - Opening command 1-4 - Closing command 1-5 - Step-by-step command P3 - Partial opening command 1-9 - STOP command If only one (any) CH key of the remote control is stored, command 1-3 (step-by-step/opening) is carried out.
7.8 Second level menu - SF (Special Functions) ǩ XVLQJ NH\V Ǵ DQG Ƕ VHOHFW WKH GHVLUHG IXQFWLRQ ǩ SUHVV WKH (17(5 NH\ WR FRQȌUP Display Description CU - Displaying the control panel firmware version. → → → (example) Release 1.1 [esempio] SV - Saving user configuration on control panel storage module. → → → → → 2” [esempio] (example) By selecting → → you can save up to 2 personalised configurations in memory positions and only with the storage module present on the control panel.
7.8.1 Third level menu - SF (Special Functions) Access the third level menu by activating function Display (see paragraph 7.4) Description SP - Setting the password. → → → → → 2” (example) [esempio] N.B.: this can only be selected when the password is not set. Setting the password prevents unauthorised personnel from accessing selections and adjustments. You can delete the set password by selecting the sequence JR1=ON, JR1=OFF, JR1=ON. IP - Inserting the password.
7.9 Second level menu - CC (Cycles Counter) ǩ XVLQJ NH\V Ǵ DQG Ƕ VHOHFW WKH GHVLUHG IXQFWLRQ ǩ SUHVV WKH (17(5 NH\ WR FRQȌUP Display Description CV - Display of total operations counter. → → → → (example) 182 operations manovre [esempio] CP - Display of partial operations counter. → → → → operations (example) 716 manovre [esempio] CH - Display of power supply hour counter.
7.9.1 Third level menu - CC (Cycles Counter) Access the third level menu by activating function Display (see paragraph 7.4) Description CA - Setting the maintenance alarm. You can set the required number of operations (regarding the partial operations counter) for signalling the maintenance alarm. When the set number of operations is reached, the alarm message appears on the display .
7.10 Second level menu - AP (Advanced Parameters) ǩ XVLQJ NH\V Ǵ DQG Ƕ VHOHFW WKH GHVLUHG IXQFWLRQ ǩ SUHVV WKH (17(5 NH\ WR FRQȌUP Description FA - Selection of opening limit switch mode. NO - None SX - Stop limit switch (after activation the door wing stops its movement) PX - Proximity limit switch (after activation the door wing continues as far as the end stop and any obstacle is considered a stop) (with standard limit switches) FC - Selection of closing limit switch mode.
Display Description DS - Setting of display visualisation mode. 00 - No display 01 - Commands and safety devices with radio test (see paragraph 8.2). Display of count down to automatic closing. 02 - Automation status (see paragraph 8.1) 03 - Commands and safety devices (see paragraph 8.2) WARNING: depending on the type of automation and control panel, some menus may not be available. N.B.
7.10.1 Third level menu - AP (Advanced Parameters) Access the third level menu by activating function Description DO - Setting of disengagement on stop during opening. [mm] 00 - Minimum 10 - Maximum N.B.: Not active if → DC - Setting of disengagement on stop during closing. [mm] 00 - Minimum 10 - Maximum N.B.: Not active if → 02 02 OT - Selection of type of obstacle. 00 - Overcurrent or door stopped 01 - Overcurrent 02 - Door stopped CR - Correction to calculated speed.
Display Description TN - Setting of intervention temperature for NIO antifreeze system. [°C] Adjustment of the working temperature of the control panel. The value does not refer to ambient temperature. TB - Display of working temperature of control panel. DO NOT USE WO - Setting of pre-flashing time on opening. [s] Adjustment of the lead time for the switch-on of the flashing light, in relation to the start of the opening operation from a voluntary command.
8. Display visualisation mode WARNING: depending on the type of automation and control panel, some menus may not be available. i Display of automation status The automation status display mode is only visible with Display visualisation mode set to 02. → → Display Description → Automation closed. Automation closed. Release door open. Automation open. Automation open. Release door open. Automation stopped in intermediate position. Automation stopped in intermediate position. Release door open.
Display Description → Automation closed. Automation closed. Release door open. Automation open. Automation open. Release door open. Automation stopped in intermediate position. Automation stopped in intermediate position. Release door open. Automation closing. Automation that slows down during closing. Automation opening. IP2162EN - 2014-04-17 Automation that slows down during opening.
i Display of safety devices and commands The safety device and command display mode is only visible with Display visualisation mode set to 01 or 03. → → → → Display Description 1-3 - Opening command. 1-4 - Closing command. 1-5 - Step-by-step command. 1-6 - Safety device with opening and closing stop. 1-8 - Safety with closing reversal. P3 - Partial opening command. 3P - Opening command with operator present. 4P - Closing command with operator present.
F2 - Opening limit switch O1 - Detection of an obstacle during closing O2 - Detection of an obstacle during opening OO - Reaching of obstacle detection limit during opening OC - Reaching of obstacle detection limit during closing S1 - Detection of stop during closing S2 - Detection of stop during opening SW - Release door open. When the release door is closed, the control panel performs a RESET (alarm ) RV - Enabling/disabling of built-in radio receiver via JR3.
8.3 Display of alarms and faults i Alarms and faults can be displayed with any display selection. The signalling of alarm messages takes priority over all other displays. Type of alarm Display Description M0 - Selected motor not suitable. Operation Set correct motor wiring. M3 - Automation blocked (open/closed) Check the mechanical parts M4 - Motor short circuit Check the motor is correctly connected. Mechanical alarm Check the motor is working properly.
Power supply operations alarm Type of alarm Display Description Operation R3 - Storage module not detected (with Insert a working storage module or set JR3=ON). JR3=OFF. R5 - Storage module not working (re- Replace the storage module. gardless of JR3) A0 - Failure of test of safety sensor on Check that device SOFA1-A2/GOPAV is contact 6. working correctly.
Type of alarm Display Description Operation Control panel internal alarm IM - Shortcircuited motor MOSFET Reset. alarm If the problem persists, contact Technical Support. IO - Interrupted power circuit (motor Reset. MOSFET open) If the problem persists, contact Technical Support. IR- Motor relay malfunctioning Reset. If the problem persists, contact Technical Support. V0 - Request for maintenance interven- Proceed with the scheduled maintetion nance intervention.
9. Start-up WARNING The operations related to point 5 are performed without safety devices. The display parameters can only be adjusted when the automation is idle. The automation automatically slows when approaching the end stops or stop limit switches. At every start-up the control panel receives a RESET and the first operation is performed at reduced speed (automation position acquisition). 1- Make a jumper for NC safety contacts. 2- Adjust the opening and closing stop limit switches, if any. N.B.
10. Troubleshooting Possible cause Alarm signalling The automation does not No power. open or close. Operation Check power supply cable. Short circuited accessories. Disconnect all accessories from terminals 0-1 (a voltage of 24V= must be present) and reconnect them one at a time. Contact Technical Service Blown line fuse. Replace fuse. Safety contacts are open. Check that the safety contacts are closed correctly (NC).
The automation opens/clos- There is a presence of friction. es briefly and then stops. Manually check that the automation moves freely and check / adjustment the Contact Technical Service The remote control has lim- The radio transmission is imited range and does not work peded by metal structures and with the automation moving. reinforced concrete walls. Install the antenna outside. Replace the transmitter batteries. The remote control does not No storage module or incorwork rect storage module.
11.
IP2162EN - 2014-04-17 $OO WKH ULJKWV FRQFHUQLQJ WKLV PDWHULDO DUH WKH H[FOXVLYH SURSHUW\ RI (QWUHPDWLF *URXS $% $OWKRXJK WKH FRQWHQWV RI WKLV SXEOLFDWLRQ KDYH EHHQ GUDZQ XS ZLWK WKH JUHDWHVW FDUH (QWUHPDWLF *URXS $% FDQQRW EH KHOG UHVSRQVLEOH LQ DQ\ ZD\ IRU DQ\ GDPDJH FDXVHG E\ PLVWDNHV RU RPLVVLRQV LQ WKLV SXEOLFDWLRQ :H UHVHUYH WKH ULJKW WR PDNH FKDQJHV ZLWKRXW SULRU QRWLFH &RS\LQJ VFDQQLQJ DQG FKDQJLQJ LQ DQ\ ZD\ DUH H[SUHVVO\ IRUELGGHQ XQOHVV DXWKRULVHG LQ ZULWLQJ E\ (QWUHPDWLF *URXS $% 93
IP2162EN - 2014-04-17 Entrematic Group AB Lodjursgatan 10 SE-261 44, Landskrona Sweden www.ditecentrematic.
IP2162EN Quick Reference Ditec CS12E Quick guide for standard installation of Ditec CS12E automation with Ditec CS12E control panel Read the instructions carefully before installing the product. Bad installation could be dangerous. For different setting and further informations consult the installation manuals of Ditec NeoS, control panel Ditec CS12 and the accessories too.
Installation type SofA LampH 2x1,5 mm² RG58 SofA Xel2 4x0,5 mm² Power supply Xel5 3x1,5 mm² blu giallo-verde marrone Xel2 4x0,5 mm² 4x0,5 mm² Gol4
Accessories XEL2 TX RX 01 01 JR3 C NO NC AUX 1 5 XEL5 0 1 6 8 4x0,5 mm² +LP- LAMPH 14 0 2x1,5 mm² RG58 max 10 m SOFA1-A2 GOPAVRS JR3 AUX 8K2 8K2 OUT1 OUT2 GOPAVT IN1 IN2 +BC - 1 41 IN1 IN2 OUT2 +LP- OUT1 1 5 IN2 +LP- ENTER GOPAVRS IN1 DOWN 0 1 6 8 1 41 1 5 SOFA1-SOFA2 0 1 6 8 UP AUX JR3
Selection of opening direction Opening to the right (factory settings) x2 s Opening to the left x2 s Radio enabling x1, x2, ...