Figure 71. UPS
Power On Sequence:
1. On the Emergency Stop Panel (see Figure 70, Point 6), ensure the Main Breaker
(CB1) is in the [ON] position.
2. On the Emergency Stop Panel (see Figure 70, Point 7), ensure the Pedestal Breaker
(CB2) is in the [ON] position.
3. On the Radar System UPS (see Figure 71, Point 1), press and hold the power button
until the UPS power on.
4. Wait for the Power Distribution and Control Unit (see paragraph 1.1.6) to power on
(approximately 2 minutes).
5. Press and hold the E-Stop Reset Button (see Figure 70, Point 1) for 2-3 seconds, then
release.
When the pedestal is initially powered on it will begin a warm-up and alignment process. The pedestal
will rotate in azimuth as well as move up and down in elevation following a pre-programmed homing
sequence. At the end of the homing process, the pedestal will rotate in azimuth until it reaches its home
position, which is a variable position. The pedestal may pause at this position for a brief moment.
6. Ensure the power to the system is active by checking the various components in the
Control Cabinet and verifying the lights (see Figure 70, Point 3, 4, and 5) are
illuminated.
a. Ensure the KVM monitor displays the blue and magenta login screen (see Figure
72, below.)