1.1.10.7. 12VDC Power Supply (Unit 1 A10 PS4)
The 12VDC Power Supply (PS4) provides all the 12VDC voltage for the Antenna / Pedestal
Assembly.
(See Figure 13, Point 7)
1.1.11. E-Stop Panel (Unit 1 A11)
The E-Stop Control panel contains the E-Stop Reset button, the E-Stop Button, Power Indicators,
and two Circuit Breakers. The Main Power circuit breaker (CB1) controls power to the entire
system. The Pedestal Power circuit breaker (CB2) controls the power to the DC Power
Distribution Plate (see paragraph 1.1.10).
Figure 16. Emergency Stop Panel (134933-100)
1.
E
-
Stop Reset Button (2XVT5)
2. E-Stop Button
(704-0742)
(704-9631)
(704-9104)
3. Input Power LED – L1 (679-9774)
4. Main Power LED – L2 (679-9774)
5. Pedestal Power LED – (679-9774)
6. Circuit Breaker – Main – 50A (683-0035)
7. Circuit Breaker – Pedestal – 10A (683-0037)