1.
Terminal Block End Stop (CA702)
2. Fuse Block (3 Each), (CAFL4U)
3. Power Supply, 24 VDC (DPP100-24)
4. Ethernet Switch, 7-Port, 1 FO (EDS-308-M-SC-T)
1.1.8.1. 7-Port Ethernet Switch with 1-Fiber Optic Port (Unit 1 A8 A1)
The Ethernet Switch with Fiber-Optic Media Converter provides network access to the RCU
computer for the Analog and Discrete Input Modules and converts a fiber-optic connection to
Ethernet. The fiber-optic connection extends Ethernet connectivity to the Antenna/Pedestal.
1.1.8.2. 24VDC Power Supply (Unit 1 A8 PS1)
The 24 VDC power supply provides power to the 7-Port Ethernet Switch. See also paragraph
1.1.10.4.
1.1.9. UPS, 2000/1800 KVA (Unit 1 A9)
The 2KVA Uninterruptable Power Supply (UPS) provides adequate power for the Control
Cabinet. The 2KVA UPS provides backup power and line conditioning for the all components in
the Control Cabinet.
Figure 12. UPS, Powerware Model 9130, (PW9130I2000R-XL)