1. Step 1:
The Regeneration Clamp will prevent power from reaching the Servo Controller and the
Servo Amplifier. Check the input Voltage (V IN + and V IN -) to ensure input power is
available. If not, troubleshoot power through the Pedestal at Terminal Block 1 (TB1).
Maintenance:
1. Step 1:
Remove the Screws (12 Philips Screws) retaining the cover where the regeneration
clamp is mounted. (See Figure 10, red circles)
Figure 10. Regeneration Clamp
This will removed the cover where the Regeneration Clamp is mounted.
2. Step 2:
Remove the four (4) screws connecting the Regeneration Clamp to the cover.
3. Step 3:
Remove all cable connections.
4. Step 4:
Reinstall the Regeneration Clamp in reverse order of Steps 1-3.