Check the connectors, J6 and J7. Are the connectors inserted properly?
NO: Reinsert and restart this step.
YES: Go to Step 3.
3. Step 3 (Communication):
Are the Ethernet (J3) and RS232 (J4) connectors inserted properly?
NO: Reinsert and restart this step.
YES: Go to Step 4.
4. Is the Ethernet Switch (Unit 2 A1 A3 A1 A5) functioning properly (See Paragraph
2.1.3.1.4)
NO: Repair the Ethernet Switch per Paragraph 2.1.3.1.4)
YES: End Process.
Maintenance:
Remove and Replace:
Figure 9. Servo Amplifier Removal
1. Step 1:
Open the Elevation Assembly FRONT Cover using a Philips Screwdriver (12 Screws).
See Figure 9, Point 1.
Do not remove the cover where the Regeneration Clamp is mounted.