User's Manual Part 1
T
ECHNICAL
D
OCUMENTATION
P
ROTECTING
P
EOPLE AND
A
SSETS
®
D
ATE
:
22
M
ARCH
2017
|
V
ERSION
:
1.4
23
R
ANGER
-X5
R
ADAR
S
YSTEM
T
ROUBLESHOOTING
,
M
AINTENANCE
,
AND
C
ALIBRATION
EEC
®
|
C
OMPANY
P
ROPRIETARY
1. Step 1:
Using a voltmeter, measure the input AC Voltage on Terminal Block 1, point 9, 10, and
11. Is AC Voltage Present?
NO: Troubleshoot the input power, then return to this step.
YES: Go to Step 2.
2. Step 2:
Using a voltmeter, measure the input DC Voltage on Terminal Block 2, point 6 and 7. Is
DC Voltage Present?
NO: Replace the Power Supply.
YES: Go to Paragraph 1.11.7
Maintenance:
To replace the Power Supply:
1. Disconnect ALL the terminals / wires from the input and output of the Power Supply.
2. Using a Philips Head screwdriver, loosen the screws connecting the Power Supply to the
Plate.
3. Remove the Power Supply from the Plate.
4. Reinstall in reverse order of Steps 1-3.
Calibration:
None
1.11.7. 12VDC Power Supply (Unit 1 A13 PS4)
Troubleshooting:
SD-134932-101 Sheet 1 of 1
1. Step 1:
Using a voltmeter, measure the input AC Voltage on Terminal Block 1, point 9, 10, and
11. Is AC Voltage Present?
NO: Troubleshoot the input power, then return to this step.
YES: Go to Step 2.
2. Step 2:
Using a voltmeter, measure the input DC Voltage on Terminal Block 2, point 8 and 9. Is
DC Voltage Present?
NO: Replace the Power Supply.
YES: Return to Paragraph
Maintenance: