User's Manual
CHAPTER 8 INTERFACE CONTROL DOCUMENTS (ICD)
APPENDIX A INTERFACE CONTROL DOCUMENTS (ICD)
ISSUE/REVISION DATE: 25 JULY 2007 TECHNICAL MANUAL
ISO 9001:2000 PROPRIETARY
Interface Control Document (ICD) ENTERPRISE ELECTRONICS CORPORATION
Rev No. 5 Page 13 of 21
Issue Date 25 July 2007 UM-130365
Distribution Data Collection
Module (DDC)
THE DATA PRESENTED HEREIN REPRESENTS THE INTELLECTUAL PROPERTY OF ENTERPRISE ELECTRONICS CORPORATION (EEC). THIS DATA MAY NOT BE DISTRIBUTED OR REPRODUCED BY
ANY MEANS WITHOUT THE EXPRESS, WRITTEN CONSENT OF EEC.
4.0 Troubleshooting the DDC
4.1 LED indicators
LED1
&
2
RS232
The DDC module has three LEDs that are used for the following indications:
Indica-
tor
Function
LED 1 Processor running. This LED should blink regularly.
LED 2 Communications link established. This LED should blink regularly.
RS232 RS232 receive level present. This LED should be lit when a good RS232 receive level is detected on
any of the three RS232 ports.