User`s guide
Table Of Contents
- Title
- Notice
- Contents
- Figures
- Tables
- About This Guide
- Introduction
- Local Management Requirements
- Accessing Local Management
- 3.1 Navigating Local Management Screens
- 3.2 Password Screen
- 3.3 Main Menu Screen
- 3.4 Module Selection Screen
- 3.5 Module Menu Screen
- 3.6 Overview of Security Methods
- 3.7 Security Menu Screen
- 3.8 Passwords Screen
- 3.9 Radius Configuration Screen
- 3.10 Name Services Configuration Screen
- 3.11 System Authentication Configuration Screen
- 3.12 EAP (Port) Configuration Screen
- 3.13 EAP Statistics Menu Screen
- 3.14 MAC Port Configuration Screen
- 3.15 MAC Supplicant Configuration Screen
- Chassis Menu Screens
- 4.1 Chassis Menu Screen
- 4.2 Chassis Configuration Screen
- 4.3 SNMP Configuration Menu Screen
- 4.4 SNMP Community Names Configuration Screen
- 4.5 SNMP Traps Configuration Screen
- 4.6 Chassis Environmental Information Screen
- 4.7 Redirect Configuration Menu Screen (Chassis)
- 4.8 Port Redirect Configuration Screen
- 4.9 VLAN Redirect Configuration Screen
- Module Configuration Menu Screens
- 5.1 Module Configuration Menu Screen
- 5.2 General Configuration Screen
- 5.2.1 Setting the IP Address
- 5.2.2 Setting the Subnet Mask
- 5.2.3 Setting the Default Gateway
- 5.2.4 Setting the TFTP Gateway IP Address
- 5.2.5 Setting the Module Name
- 5.2.6 Setting the Module Date
- 5.2.7 Setting the Module Time
- 5.2.8 Entering a New Screen Refresh Time
- 5.2.9 Setting the Screen Lockout Time
- 5.2.10 Configuring the COM Port
- 5.2.11 Clearing NVRAM
- 5.2.12 Enabling/Disabling IP Fragmentation
- 5.3 SNMP Configuration Menu Screen
- 5.4 SNMP Community Names Configuration Screen
- 5.5 SNMP Traps Configuration Screen
- 5.6 Access Control List Screen
- 5.7 System Resources Information Screen
- 5.8 FLASH Download Configuration Screen
- Port Configuration Menu Screens
- 6.1 Port Configuration Menu Screen
- 6.2 Ethernet Interface Configuration Screen
- 6.3 Ethernet Port Configuration Screen
- 6.4 HSIM/VHSIM Configuration Screen
- 6.5 Redirect Configuration Menu Screen
- 6.6 Port Redirect Configuration Screen
- 6.7 VLAN Redirect Configuration Screen
- 6.8 Link Aggregation Screen (802.3ad Main Menu Screen)
- 6.9 Broadcast Suppression Configuration Screen
- 802.1 Configuration Menu Screens
- 802.1Q VLAN Configuration Menu Screens
- 8.1 Summary of VLAN Local Management
- 8.2 802.1Q VLAN Configuration Menu Screen
- 8.3 Static VLAN Configuration Screen
- 8.4 Static VLAN Egress Configuration Screen
- 8.5 Current VLAN Configuration Screen
- 8.6 Current VLAN Egress Configuration Screen
- 8.7 VLAN Port Configuration Screen
- 8.8 VLAN Classification Configuration Screen
- 8.9 Protocol Port Configuration Screen
- 802.1p Configuration Menu Screens
- 9.1 802.1p Configuration Menu Screen
- 9.2 Port Priority Configuration Screen
- 9.3 Traffic Class Information Screen
- 9.4 Traffic Class Configuration Screen
- 9.5 Transmit Queues Configuration Screen
- 9.6 Priority Classification Configuration Screen
- 9.7 Protocol Port Configuration Screen
- 9.8 Rate Limiting Configuration Screen
- Layer 3 Extensions Menu Screens
- Module Statistics Menu Screens
- Network Tools Screens
- VLAN Operation and Network Applications
- 13.1 Defining VLANs
- 13.2 Types of VLANs
- 13.3 Benefits and Restrictions
- 13.4 VLAN Terms
- 13.5 VLAN Operation
- 13.6 Configuration Process
- 13.7 VLAN Switch Operation
- 13.8 VLAN Configuration
- 13.9 Summary of VLAN Local Management
- 13.10 Quick VLAN Walkthrough
- 13.11 Examples
- 13.12 Example 1, Single Switch Operation
- 13.13 Example 2, VLANs Across Multiple Switches
- 13.14 Example 3, Filtering Traffic According to a Layer 4 Classification Rule
- 13.15 Example 4, Securing Sensitive Information According to Subnet
- 13.16 Example 5, Using Dynamic Egress to Control Traffic
- 13.17 Example 6, Locking a MAC Address to a Port Using Classification Rules
- Generic Attribute Registration Protocol (GARP)
- About IGMP
- Index

Port Redirect Configuration Screen
6-16 Port Configuration Menu Screens
6.6 PORT REDIRECT CONFIGURATION SCREEN
When to Use (for 6C105 Chassis)
To redirect frames from one source port to many destination ports or many source ports to one
destination port on a switch module in a 6C105 chassis. Frames received on a source port can be
redirected and transmitted in the frame format in which they are received (normal), or they can be
redirected with a VLAN Tag (TAGGED) or without a VLAN Tag (UNTAGGED). Also, any
errored frames received can be either dropped or forwarded to a destination port.
For example, port 1 can be set as the source port with ports 2 and 5 as the destination ports. Frames
from port 1 are then automatically redirected to ports 2 and 5 according to the configured frame
format, and frames with errors can be either forwarded or dropped according to the screen settings.
The port redirect function is useful for troubleshooting purposes. It allows all inbound and
outbound traffic from one or more source ports to be sent to a destination port where all current
traffic from the source ports can be examined using analyzers, RMON probes, or IDS sensors.
When to Use (for 6C107 Chassis)
To redirect frames in modules installed in a 6C107 chassis. The information above applies to
modules installed in the 6C105 chassis. However, when configuring 6000 series modules installed
in a 6C107 chassis, there are special considerations to take into account when redirecting many
ports to one port, or one port to many ports.
When installing 6X2XX modules into the 6C107 chassis, note the following:
• There are no restrictions when all modules in the 6C107 chassis are 6X3XX series and 6X2XX
series modules
• Redirecting ports between 6X3XX series and 6X2XX series modules is only possible when all
modules are installed in slots one through five.
NOTE: The switch module supports a maximum of 128 redirect entries configured
including VLAN redirect, port redirect and, if the module has an optional ATM interface
installed, any ATM Permanent Virtual Circuits (PVCs) redirect entries.
NOTE: Although all redirected traffic (including, if desired, errored frames) from a
source port are sent to the destination port, normal switching is still performed for all
frames on the source ports.