User`s guide
Table Of Contents
- Title
- Notice
- Contents
- Figures
- Tables
- About This Guide
- Introduction
- Local Management Requirements
- Accessing Local Management
- 3.1 Navigating Local Management Screens
- 3.2 Password Screen
- 3.3 Main Menu Screen
- 3.4 Module Selection Screen
- 3.5 Module Menu Screen
- 3.6 Overview of Security Methods
- 3.7 Security Menu Screen
- 3.8 Passwords Screen
- 3.9 Radius Configuration Screen
- 3.10 Name Services Configuration Screen
- 3.11 System Authentication Configuration Screen
- 3.12 EAP (Port) Configuration Screen
- 3.13 EAP Statistics Menu Screen
- 3.14 MAC Port Configuration Screen
- 3.15 MAC Supplicant Configuration Screen
- Chassis Menu Screens
- 4.1 Chassis Menu Screen
- 4.2 Chassis Configuration Screen
- 4.3 SNMP Configuration Menu Screen
- 4.4 SNMP Community Names Configuration Screen
- 4.5 SNMP Traps Configuration Screen
- 4.6 Chassis Environmental Information Screen
- 4.7 Redirect Configuration Menu Screen (Chassis)
- 4.8 Port Redirect Configuration Screen
- 4.9 VLAN Redirect Configuration Screen
- Module Configuration Menu Screens
- 5.1 Module Configuration Menu Screen
- 5.2 General Configuration Screen
- 5.2.1 Setting the IP Address
- 5.2.2 Setting the Subnet Mask
- 5.2.3 Setting the Default Gateway
- 5.2.4 Setting the TFTP Gateway IP Address
- 5.2.5 Setting the Module Name
- 5.2.6 Setting the Module Date
- 5.2.7 Setting the Module Time
- 5.2.8 Entering a New Screen Refresh Time
- 5.2.9 Setting the Screen Lockout Time
- 5.2.10 Configuring the COM Port
- 5.2.11 Clearing NVRAM
- 5.2.12 Enabling/Disabling IP Fragmentation
- 5.3 SNMP Configuration Menu Screen
- 5.4 SNMP Community Names Configuration Screen
- 5.5 SNMP Traps Configuration Screen
- 5.6 Access Control List Screen
- 5.7 System Resources Information Screen
- 5.8 FLASH Download Configuration Screen
- Port Configuration Menu Screens
- 6.1 Port Configuration Menu Screen
- 6.2 Ethernet Interface Configuration Screen
- 6.3 Ethernet Port Configuration Screen
- 6.4 HSIM/VHSIM Configuration Screen
- 6.5 Redirect Configuration Menu Screen
- 6.6 Port Redirect Configuration Screen
- 6.7 VLAN Redirect Configuration Screen
- 6.8 Link Aggregation Screen (802.3ad Main Menu Screen)
- 6.9 Broadcast Suppression Configuration Screen
- 802.1 Configuration Menu Screens
- 802.1Q VLAN Configuration Menu Screens
- 8.1 Summary of VLAN Local Management
- 8.2 802.1Q VLAN Configuration Menu Screen
- 8.3 Static VLAN Configuration Screen
- 8.4 Static VLAN Egress Configuration Screen
- 8.5 Current VLAN Configuration Screen
- 8.6 Current VLAN Egress Configuration Screen
- 8.7 VLAN Port Configuration Screen
- 8.8 VLAN Classification Configuration Screen
- 8.9 Protocol Port Configuration Screen
- 802.1p Configuration Menu Screens
- 9.1 802.1p Configuration Menu Screen
- 9.2 Port Priority Configuration Screen
- 9.3 Traffic Class Information Screen
- 9.4 Traffic Class Configuration Screen
- 9.5 Transmit Queues Configuration Screen
- 9.6 Priority Classification Configuration Screen
- 9.7 Protocol Port Configuration Screen
- 9.8 Rate Limiting Configuration Screen
- Layer 3 Extensions Menu Screens
- Module Statistics Menu Screens
- Network Tools Screens
- VLAN Operation and Network Applications
- 13.1 Defining VLANs
- 13.2 Types of VLANs
- 13.3 Benefits and Restrictions
- 13.4 VLAN Terms
- 13.5 VLAN Operation
- 13.6 Configuration Process
- 13.7 VLAN Switch Operation
- 13.8 VLAN Configuration
- 13.9 Summary of VLAN Local Management
- 13.10 Quick VLAN Walkthrough
- 13.11 Examples
- 13.12 Example 1, Single Switch Operation
- 13.13 Example 2, VLANs Across Multiple Switches
- 13.14 Example 3, Filtering Traffic According to a Layer 4 Classification Rule
- 13.15 Example 4, Securing Sensitive Information According to Subnet
- 13.16 Example 5, Using Dynamic Egress to Control Traffic
- 13.17 Example 6, Locking a MAC Address to a Port Using Classification Rules
- Generic Attribute Registration Protocol (GARP)
- About IGMP
- Index

General Configuration Screen
Module Configuration Menu Screens 5-9
Figure 5-3 Configuration Warning Screen, IP Address
5. Use the arrow keys to highlight the YES command, then press ENTER. The changes are saved
and the module reboots.
5.2.2 Setting the Subnet Mask
If the management workstation that is to receive SNMP traps from the switch module is located on
a separate subnet, the subnet mask for the switch module may need to be changed from its default
value.
To change the subnet mask from its default, perform the following steps:
1. Use the arrow keys to highlight the Subnet Mask field.
2. Enter the subnet mask into this field using Dotted Decimal Notation (DDN) format.
For example: 255.255.0.0
3. Press ENTER. If the subnet mask is valid, the cursor returns to the beginning of the Subnet Mask
field. If the entry is not valid, the screen displays the message “INVALID SUBNET MASK OR
FORMAT ENTERED”. Local Management does not alter the current value, but it does refresh
the Subnet Mask field with the previous value.
WARNING!
19601-84
YOU HAVE ELECTED TO SAVE ONE OR MORE CONFIGURATION
ITEMS THAT REQUIRE RESETTING THIS DEVICE.
ARE YOU SURE YOU WANT TO CONTINUE?
YES
NO