SecureStack C2 Redundant Power System C2RPS-SYS Installation Guide C2RPS-PSM Power C2RPS-CHAS8 Caution: Do not use this product with SecureStack C2 PoE devices. Any SecureStack C2 device with a “P” suffix in the model number (C2xxxx-xxP) indicates a SecureStack C2 PoE-compliant device and is not compatible with this power system. Precaución: El RPS no es compatible con switches SecureStack C2 con PoE.
Electrical Hazard: Only qualified personnel should perform installation procedures. Advertencia eléctrica: Solamente personal calificado debe realizar procedimientos de instalacion. Elektrischer Gefahrenhinweis: Installationen sollten nur durch ausgebildetes und qualifiziertes Personal vorgenommen werden. Notice Enterasys Networks reserves the right to make changes in specifications and other information contained in this document and its web site without prior notice.
Regulatory Compliance Information Federal Communications Commission (FCC) Notice This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. NOTE: This equipment has been tested and found to comply with the limits for a class A digital device, pursuant to Part 15 of the FCC rules.
Electromagnetic Compatibility (EMC) This product complies with the following: 47 CFR Parts 2 and 15, CSA C108.8, 89/336/EEC, EN 55022, EN 61000‐3‐2, EN 61000‐3‐3, EN 55024, AS/NZS CISPR 22, VCCI V‐3. Compatibilidad Electromágnetica (EMC) Este producto de Enterasys cumple con lo siguiente: 47 CFR Partes 2 y 15, CSA C108.8, 89/336/EEC, EN 55022, EN 55024, EN 61000‐3‐2, EN 61000‐3‐3, AS/NZS CISPR 22, VCCI V‐3.
Declaration of Conformity Application of Council Directive(s): Manufacturer’s Name: Manufacturer’s Address: European Representative Address: Conformance to Directive(s)/Product Standards: Equipment Type/Environment: 89/336/EEC 73/23/EEC Enterasys Networks, Inc. 50 Minuteman Road Andover, MA 01810 USA Enterasys Networks, Ltd.
Enterasys Networks, Inc. Firmware License Agreement BEFORE OPENING OR UTILIZING THE ENCLOSED PRODUCT, CAREFULLY READ THIS LICENSE AGREEMENT. This document is an agreement (“Agreement”) between the end user (“You”) and Enterasys Networks, Inc.
3. APPLICABLE LAW. This Agreement shall be interpreted and governed under the laws and in the state and federal courts of the Commonwealth of Massachusetts without regard to its conflicts of laws provisions. You accept the personal jurisdiction and venue of the Commonwealth of Massachusetts courts.
8. AUDIT RIGHTS. You hereby acknowledge that the intellectual property rights associated with the Program are of critical value to Enterasys and, accordingly, You hereby agree to maintain complete books, records and accounts showing (i) license fees due and paid, and (ii) the use, copying and deployment of the Program.
viii
Contents About this Guide Using This Guide ................................................................................................................................. xi Structure of This Guide ........................................................................................................................ xi Using the SecureStack C2 Manual Set ............................................................................................... xii Conventions Used in This Guide .....................
Figures 1-1 1-2 1-3 1-4 1-5 2-1 2-2 2-3 2-4 2-5 A-1 SecureStack C2RPS-CHAS8 (front view without PSMs).......................................................1-2 SecureStack C2RPS-CHAS8 (rear view with eight PSMs)....................................................1-2 C2RPS-PSM (front view) .......................................................................................................1-3 C2RPS-PSM (rear view) ............................................................................................
About this Guide This guide provides an overview, installation and troubleshooting instructions, and specifications for the Enterasys SecureStack C2RPS‐SYS redundant power system components: chassis (C2RPS‐CHAS8), power supply module (C2RPS‐PSM), DC power cables (C2RPS‐PSM Cable), and AC power cords. Note: In this document, the following terms are used: • RPS refers to the complete SecureStack C2RPS-SYS redundant power system. • Chassis refers to the C2RPS-CHAS8 chassis.
Using the SecureStack C2 Manual Set Using the SecureStack C2 Manual Set Other manuals have been developed for the SecureStack C2 non‐PoE switch devices that can be connected to the RPS for power redundancy. Caution: The RPS does not support PoE-compliant SecureStack switches. Do not try to connect the power cable from this RPS to any SecureStack switch with a “P” suffix in the model name, such as C2xxxxx-xxP. Otherwise, damage to the device may result.
Conventions Used in This Guide Conventions Used in This Guide The following conventions are used in this guide: Note: Calls the reader’s attention to any item of information that may be of special importance. Caution: Contains information essential to avoid damage to the equipment. Precaución: Contiene información esencial para prevenir dañar el equipo. Achtung: Verweißt auf wichtige Informationen zum Schutz gegen Beschädigungen.
Conventions Used in This Guide xiv About this Guide
1 Introduction This chapter provides a functional overview of the Redundant Power System (RPS), which includes the following: For information about... Refer to page... RPS Overview 1-1 C2RPS-CHAS8 Chassis 1-2 C2RPS-PSM Power Supply Module 1-3 RPS Deployment Strategies 1-4 Getting Help 1-5 RPS Overview The RPS provides a simple and economical solution for providing a backup power source for up to eight SecureStack Ethernet switch devices.
RPS Overview C2RPS-CHAS8 Chassis The chassis is a an eight‐slot frame without AC power connections or electronics. The chassis can be installed in a standard 19‐inch rack and populated with up to eight PSMs. Each PSM operates independently. Figure 1‐1 shows the front view of the chassis with covers only; Figure 1‐2 shows the rear view if the chassis was fully populated with PSMs.
RPS Overview C2RPS-PSM Power Supply Module The PSM provides the following: • Hot swap capability. • One 12 Vdc, 150 Watts of maximum‐continuous power output to a connected SecureStack C2 switch device. • Front panel Status LED that indicates if the PSM is operating correctly. Figures 1‐3 and 1‐4 show the front and rear view of the C2RPS‐PSM.
RPS Deployment Strategies RPS Deployment Strategies The RPS can be deployed in a variety of situations with mission‐critical applications. For example: • For use in a voice and data network where switches are connected to IP phones and PCs. Connecting an RPS to the switches can prevent voice network failures caused by switch failures. • For use in traditional data 10/100/1000 Ethernet switches carrying mission‐critical data.
Getting Help Getting Help For additional support related to the devices or this document, contact Enterasys Networks using one of the following methods: World Wide Web http://www.enterasys.com/support Phone 603-332-9400 1-800-872-8440 (toll-free in U.S. and Canada) For the Enterasys Networks Support toll-free number in your country: http://www.enterasys.com/support/gtac-all.html Internet mail support@enterasys.com To expedite your message, please type [C-SERIES] in the subject line.
Getting Help 1-6 Introduction
2 Installation Electrical Hazard: Only qualified personnel should perform installation procedures. Advertencia eléctrica: Solamente personal calificado debe realizar procedimientos de instalacion. Elektrischer Gefahrenhinweis: Installationen sollten nur durch ausgebildetes und qualifiziertes Personal vorgenommen werden. This chapter provides the installation instructions to install all the components of an RPS. To correctly install an RPS, follow the order of information listed below.
Installing C2RPS-PSMs 3. Perform a visual inspection of the switch devices for any signs of physical damage. Contact Enterasys Networks if there are any signs of damage. Refer to “Getting Help” on page 1‐5 for details.
Installing C2RPS-PSMs 5. Proceed to “Installing C2RPS‐CHAS8 into the Rack” on page 2‐4 for the rack mount installation instructions.
Installing C2RPS-CHAS8 into the Rack 3. Pull the PSM out and remove it from the chassis. 4. Repeat steps 1 through 3 for each additional PSM you plan to remove. Note: If you plan to remove and not replace a C2RPS-PSM, immediately reinstall coverplates over any empty power supply slots to prevent EMI leakage from the chassis. To install a PSM, proceed as follows: 1. Align the PSM with the slot, then slide the PSM forward until its front panel is flush against the chassis front panel. 2.
Installing C2RPS-CHAS8 into the Rack • An ambient temperature of between 5°C (41°F) and 40°C (104°F) must be maintained at the installation site with fluctuations of less than 10°C (18°F) per hour. Caution: To ensure proper ventilation and prevent overheating, leave a minimum clearance space of 101.6 cm (4.0 in.) at the front and rear of the chassis. Precaución: Para asegurar una buena ventilación y evitar que el sistema se sobrecaliente, deje un espacio mínimo de 10.16 cm (4 pulgadas.
Connecting the PSM Cables and AC Power Cords Figure 2-2 Fastening the C2RPS-CHAS8 to the Rack  Á 1 C2RPS-CHAS8 chassis 2 Rails of 19-inch rack À Power C2RPS-PSM Power C2RPS-PSM Power C2RPS-PSM Power C2RPS-PSM Power C2RPS-PSM Power C2RPS-PSM Power C2RPS-PSM C2RPS-PSM Power C2RPS-CHAS8  Á 3 Mounting screws (supplied by user) Connecting the PSM Cables and AC Power Cords The PSMs are connected to the SecureStack Ethernet switch devices using PSM cables.
Connecting the PSM Cables and AC Power Cords 5. On certain switches, an LED indicator will show that a redundant power supply is now in operation. . Note: No change in switch configuration is necessary for this installation.
Connecting the PSM Cables and AC Power Cords Figure 2-5 C2RPS-PSM Cable and AC Power Cord Connections Redundant Power Supply STACK UP AC LINE 100-240 VAC 50-60 Hz 0.8 A MAX STACK DOWN MAC ADDRESS SERIAL NO.
A Specifications This appendix provides information about the following: For information about... Refer to page... C2RPS-CHAS8 Chassis Specifications A-1 C2RPS-PSM Specifications A-2 C2RPS-PSM Redundant Power Supply Output Connector A-3 Compliance Standards A-3 Enterasys Networks reserves the right to change the specifications at any time without notice. C2RPS-CHAS8 Chassis Specifications Table A‐1 provides the physical specifications for the C2RPS‐CHAS8.
C2RPS-PSM Specifications C2RPS-PSM Specifications Refer to Table A‐2 for the input/output port specifications. Table A-2 C2RPS-PSM Specifications Item Specification Electrical AC Input Frequency Range 47 - 63 Hz AC Input Voltage Range 85 - 264 Vac Output Voltage 12 Vdc Output Current 1.0 A min., 8.5 A or 13.0 A max. Maximum Output Power 102 W or 156 W continuous Physical Dimensions 19.6 H x 5.2 W x 25.7 D (cm) 7.7 H x 2.04 W x 10.1 D (in.) Net Weight (Unit Only) 1.75 kg (3.
Compliance Standards Table A-3 C2RPS-PSM Redundant Power Supply Connector Pin Functions Pin Number Function 1 Ground 2 No connection 3 12 Vdc Output 4 12 Vdc Output 5 12 Vdc Output 6 12 Vdc Output 7 Ground 8 Ground 9 No connection 10 No connection 11 Status 1 12 Status 2 13 Power good 14 Ground Compliance Standards The C2RPS‐PSM meets the safety and electromagnetic compatibility (EMC) requirements listed in Table A‐4: Table A-4 Compliance Standards Item Standard Safety
Compliance Standards A-4 Specifications