Specifications
RMON Command Set
Alarm Group Commands
12-16 SecureStack A2 Configuration Guide
Status Whether this event entry is enabled (valid) or disabled.
Variable MIB object to be monitored.
Sample Type Whether the monitoring method is an absolute or a delta sampling.
Startup Alarm Whether alarm generated when this entry is first enabled is rising,
falling, or either.
Interval Interval in seconds at which RMON will conduct sample monitoring.
Rising Threshold Minimum threshold for causing a rising alarm.
Falling Threshold Maximum threshold for causing a falling alarm.
Rising Event Index Index number of the RMON event to be triggered when the rising
threshold is crossed.
Falling Event Index Index number of the RMON event to be triggered when the falling
threshold is crossed.
Table 12-3 show rmon alarm Output Details (Continued)
Output What It Displays...