Specifications
RMON Command Set
Alarm Group Commands
SecureStack A2 Configuration Guide 12-15
12.2.3.1 show rmon alarm
Use this command to display RMON alarm entries. The RMON alarm group periodically takes
statistical samples from RMON variables and compares them with previously configured
thresholds. If the monitored variable crosses a threshold an RMON event is generated.
show rmon alarm [index]
Syntax Description
Command Defaults
If index is not specified, information about all RMON alarm entries will be
displayed.
Command Mode
Read-Only.
Example
This example shows how to display RMON alarm entry 3:
Table 12-3 provides an explanation of the command output.
index (Optional) Displays RMON alarm entries for a specific
entry index ID.
A2(rw)->show rmon alarm 3
Index 3
---------------------
Owner = Manager
Status = valid
Variable = 1.3.6.1.4.1.5624.1.2.29.1.2.1.0
Sample Type = delta Startup Alarm = rising
Interval = 30 Value = 0
Rising Threshold = 1 Falling Threshold = 0
Rising Event Index = 2 Falling Event Index = 0
Table 12-3 show rmon alarm Output Details
Output What It Displays...
Index Index number for this alarm entry.
Owner Text string identifying who configured this entry.