Specifications

Startup and General Configuration Summary
Downloading a New Firmware Image
2-90 SecureStack A2 Configuration Guide
7. From the boot menu options screen, type 4 to load new operational code using XMODEM.
When the XMODEM transfer is complete, the following message and header information will
display:
8. From the boot menu options screen, type 2 to display the baud rate selection screen again.
9. Type 4 set the switch baud rate to 9600. The following message displays:
10.Set the terminal baud rate to 9600 and press ENTER.
11.From the boot menu options screen, type 1 to start the new operational code. The following
message displays:
[Boot Menu] 4
Ready to receive the file with XMODEM/CRC....
Ready to RECEIVE File xcode.bin in binary mode
Send several Control-X characters to cCKCKCKCKCKCKCK
XMODEM transfer complete, checking CRC....
Verified operational code CRC.
The following Enterasys Header is in the image:
MD5 Checksum....................fe967970996c4c8c43a10cd1cd7be99a
Boot File Identifier............0x0517
Header Version..................0x0100
Image Type......................0x82
Image Offset....................0x004d
Image length....................0x006053b3
Ident Strings Length............0x0028
Ident Strings...................
A2H124-24
A2H124-48
A2H124-48
Image Version Length............0x7
Image Version Bytes.............0x30 0x2e 0x35 0x2e 0x30 0x2e 0x34 (0.5.0.4)
Setting baud rate to 9600, you must change your terminal baud rate.
Operational Code Date: Tue Jun 29 08:34:05 2004
Uncompressing.....