Specifications

Configuring and Managing Time Parameters
RoamAbout Mobility System Software Configuration Guide 5-21
Displaying the Time Zone
Todisplaythetimezone,usethefollowingcommand:
show timezone
Example
Todisplaythetimezone,typethefollowingcommand:
RBT-8100# show timezone
Timezone set to 'PST', offset from UTC is -8 hours
Clearing the Time Zone
Toclearthetimezone,usethefollowingcommand:
clear timezone
Configuring the Summertime Period
Thesummertimeperiodoffsetsthesystemtime+1hourandreturnsittostandardtimefor
daylightsavingstimeorasimilarsummertimeperiodthatyouset.
Toconfigurethesummertimeperiod,usethefollowingcommand:
set summertime summer-name [start week weekday month hour min end week weekday
month hour min]
Thesummernamecanbeupto32 alphanumericcharacterslong,withnospaces.Thestartandend
datesandtimesareoptional.Ifyoudonotspecifyastartandendtime,MSSimplementsthetime
changestartingat2:00a.m.onthefirstSundayinAprilandendingat2:00
a.m.onthelastSunday
inOctober,accordingtotheNorthAmericanstandard.
Example
ThefollowingexamplesetsthesummertimeperiodtoPDT (PacificDaylightTime)andusethe
defaultstartandenddatesandtimes,typethefollowingcommand:
RBT-8100# set summertime PDT
success: change accepted.
Note: Configure summertime before you set the time and date. Otherwise, summertime’s
adjustment of the time will make the time incorrect, if the date is within the summertime period.