Use the Fault Management System to Locate a Rogue
8-16 Managing Alarms
11. SelecttheradioprofileyoucreatedandclickthePropertiesbutton.TheRadioProfile
Propertiesdialogboxisdisplayed.
12. Toenablecountermeasuresagainstroguesdetectedbyradiosmanagedbythisprofile,select
oneofthefollowingfromtheCountermeasuresModepulldownlist:
None—Radiosdonotusecountermeasures.Thisisthedefault.
All—RadiosusecountermeasuresagainstdevicesclassifiedbyMSSasroguesandagainst
devicesclassifiedbyMSSasinterferingdevices.
ArogueisadevicethatisintheEnterasysnetworkbutdoesnotbelongthere.Aninterfering
deviceisnotpartoftheEnterasysnetworkbutalsoisnotarogue.
MSSclassifiesadeviceasan
interferingdeviceifnoclientconnectedtothedevicehasbeendetectedcommunicatingwith
anynetworkentitylistedintheforwardingdatabase(FDB)ofanyRoamA boutSwitchinthe
MobilityDomain.Althoughtheinterferingdeviceisnotconnectedtoyournetwork,the
devicemight
becausingRFinterferencewithAPradios.