Table A-19 Lightning Protector Specifications
Specification Value
Mechanical
Height 2.7 in. (69 mm)
Dimension 1 in. (26 mm)
Weight 4.7 oz (133 g)
Environmental
Temperature Range (Operating and Storage) -40 to +85 °C (-40 to +185 °F)
Electrical
Frequency Range 2.0 GHz to 6.0 GHz
Return Loss > 20 dB
Insertion Loss <0.1 dB typical (<0.2 dB maximum)
Surge 10 kA IEC 1000–4–5 8/20 waveform
•VSWR < 1.2 to 1 typical (< 1.3 to 1 maximum)
Continuous Power 10 W
Let Through Voltage <
+
3 Volts for 3 kA @ 8/20 waveform
Throughput Energy <0.5 for 3 kA @ 8/20 waveform
Vibration 1 G at 5 Hz to 100 Hz
Connector Type Reverse-N (Female on both ends)