SpanningTreetopology.Byadjustingthisvalue,youcanconfiguresupportforamaximum
diameterfromtheSTProotofupto40bridges.Bydefault,Enterasysswitchingdevicesareset
withamaximumagetimeof20seconds,supportinga20bridgespanfromtherootbridge.
Usethiscommand
toadjustthemaximumagesetting:
set spantree maxage agingtime
Validagingtimevaluesare640(seconds).
Setting the Maximum Configurable STPs
Bydefault,MultipleSpanningTreemodeisgloballyenabledonEnterasysswitching devicesand
oneSpanningTreeisconfiguredasSpanningTreeID(SID)0.AsdescribedinMaximumSTP
Capacitiesonpage4,devicessupportdifferentnumbersofSpanningTreeinstances(including
SID0),dependingontheirmodeltype
andmemoryinstalled.SIDvaluesarefrom1to4094.
NSeries,SSeries,andKSeriesdevicesallowyoutosetthemaximumnumberofuserconfigured
SpanningTreesallowedonthedevice:
set spantree maxconfigurablestps numstps
ValidnumstpsvaluesforNSeries,SSeries,andKSeriesdevicesare:
•18forDFEGoldSeriesdevices
•164forDFEDiamond,DFEPlatinum,andSSeriesdevices
•132forKSeriesdevices
Enabling the Backup Root Function
DisabledbydefaultonNSeries,SSeries,stackable,andstandaloneswitchdevices,thebackup
rootfunctionworksonlywhenthebackuprootenabledbridgeisdirectlyconnectedtotheroot
bridge.ItthenpreventsstaleSpanningTreeinformationfromcirculatingthroughoutthenetwork
intheeventthatthelinkbetween
therootbridgeandthebackuprootenabledbridgeislost.Ifthis
happens,thebackuprootwilldynamicallyloweritsbridgepriorityrelativetotheexistingroot
bridgeʹspriority,causingittoimmediatelybeselectedasthenewrootbridge.
Usethiscommandtoenablethebackuprootfunction
onaSID:
set spantree backuproot sid enable
WhenSNMPtrapmessagingisconfiguredandthebackuprootfunctionisenabled,atrap
messagewillbegeneratedwhenthebackupbecomesthenewrootofthenetwork.
Adjusting RSTP Parameters
Sincerapidlinkreconfigurationcanhappenonlyonapointtopointlinkoranedgeport(aport
thatisknowntobeontheedgeofabridgedLAN),insomecasesyoumaywanttodefinethem
administratively.However,sinceedgeportandpointtopointlinksare
automaticallydetectedon
Enterasysswitchingdevices,inmostcasesyouwillnotneedtochangethesedefaultport
designations.