Specifications
set system contact Setting Basic Device Properties
Enterasys Matrix N Standalone (NSA) Series Configuration Guide 2-51
set system contact
Usethiscommandtoidentifyacontactpersonforthesystem.
Syntax
set system contact [string]
Parameters
Defaults
Ifstringisnotspecified,thecontactnamewillbecleared.
Mode
Switchcommand,Read‐Write.
Example
Thisexampleshowshowtosetthesystemcontactstring:
Matrix(rw)->set system contact “Joe Smith”
set width
Usethiscommandtosetthenumberofcolumnsfortheterminalconnectedtothedevice’sconsole
port.ThelengthoftheCLIissetusingthesetlengthcommandasdescribedin“setlength”on
page 2‐52.
Syntax
set width screenwidth
Parameters
Defaults
None.
Mode
Switchcommand,Read‐Write.
Example
Thisexampleshowshowtosettheterminalcolumnsto50:
Matrix(rw)->set width 50
string (Optional)Specifiesatextstringthatcontainsthenameofthepersonto
contactforsystemadministration.
Note: A contact string containing a space in the text must be enclosed in quotes
as shown in the example below.
screenwidth Setsthenumberofterminalcolumns.Validvaluesare50to150.