Specifications

set cep detection-id porthigh | portlow Configuring Convergence End Points (CEP) Phone Detection
Enterasys Matrix N Standalone (NSA) Series Configuration Guide 25-47
Parameters
Defaults
None.
Mode
Switchcommand,ReadWrite.
Usage
ThiscommandappliesonlytoSiemens,H.323,andSIPphonedetection.Ciscodetectionuses
CiscoDPasitsdiscoverymethod.
IfanIPaddressisnotsetforaphonedetectiongroupasdescribedinsetcepdetectionid
addressonpage 2546,thiswillconfiguredetectiononUDPand/orTCP
portsusingaportrange
definedwiththesetcep detectionidporthigh|portlowcommandasdescribedinsetcep
detectionidporthigh|portlowonpage 2547.
Example
Thisexampleshowshowtoenableboth TCPandUDPconvergenceendpointsdetectionforCEP
detectiongroup1:
Matrix>set cep detection-id 1 protocol both
set cep detection-id porthigh | portlow
UsethiscommandtosetthemaximumandminimumportsusedforTCPorUDPconvergence
endpointsdetection.
Syntax
set cep detection-id id { porthigh | portlow } port
Parameters
Defaults
None.
id Specif iesaCEPconfigurationgroupID.Thisgroupmustbecreated
andenabledusingthesetcepdetectionidcommandasdescribedin
setcepdetectionidonpage 2544.Validvaluesare1‐2147483647.
tcp|udp|both|
none
SetstheCEPIPprotocoltypeto
beusedfordetectionas:
•TCP
•UDP
•BothUDPandTCP
None
id Specif iesaCEPconfigurationgroupID.Thisgroupmustbecreated
andenabledusingthesetcepdetectionidcommandasdescribedin
setcepdetectionidonpage 2544.Validvaluesare1‐2147483647.
porthigh|portlow
port
SpecifiesamaximumorminimumUDPorTCPportfor
CEP
detection.Validvaluesare1‐65535.