Installation guide
Setting the Mode Switches
B-2 Mode Switch Settings and Installing Options
Figure B‐1showsthelocationofthemodeswitchesandtheswitchsettingsfornormal
operation.Theseswitchesaresetatthefactoryandrarelyneedtobechanged.
Switchdefinitionsandpositionsareasfollows:
•Switches1through6–ForEnterasys Networksuseonly.
•Switch7–ClearPersistentData.Changing
thepositionofthisswitchclearsPersistent
Dataonthenextpower‐upofthemodule.Alluser‐enteredparameters(suchastheIP
address,modulenames,andsoforth)areresettothefactorydefaultsettings.Once
themoduleresets,youcaneitherusethefactorydefaultsettingsorreenter
yourown
parameters.
•Switch8–ClearAdminPassword.Changingthepositionofthisswitchclearsthe
adminpassword,andrestoresthefactorydefaultpasswordonthenextpower‐upof
themodule.Oncethemoduleresets,youcaneitherusethefactorydefaultsettingsor
reenteryourownpassword.
Figure B-1 Mode Switch Location
Note: Do not change the position of Switch 8 unless it is necessary to reset the admin
password to its factory default setting.