Setup guide
Powering Up a Matrix E7 Chassis with Power Supplies
3-16
Figure 3-9 Connecting the 15-Amp AC Power Cords to the 6C207-3
2. Plug the other end of the 20 A power cord into a dedicated 20 A/120 Vac receptacle for the
6C207-1. For the 6C207-3, plug each of the two power cords into separate dedicated
15 A/115 Vac receptacles. Set the 0/| Power switch on the front panel of the power supply to |.
3. Ensure that the Power LED is green.
4. Ensure that all fans in the fan tray unit are operating properly when power is received from the
power supply modules (fan tray LED will be green). For more information on the power supply
LEDs (Power and Fan), refer to Section 2.3.
If you experience any problems with this installation, contact Enterasys Networks for assistance.
3280-01-19
50/60Hz
LINE
100-125V~12A
200-240V~6A
50/60Hz
LINE
100-125V~12A
200-240V~6A
ACON
1
0
AC ON
POWER FAN
50/60Hz
LINE
100-125V~12A
200-240V~6A
50/60Hz
LINE
100-125V~12A
200-240V~6A
ACON
1
0
AC ON
POWER FAN
115 Vac, 15A
Power Outlet
NEMA 5-15P
15 A Power
Cords (4)
Notes:
Power cords shown are for
North America only.
Each outlet must be on a
separate circuit.
115 Vac, 15A
Power Outlet
115 Vac, 15A
Power Outlet
115 Vac, 15A
Power Outlet