Installing an Optional XENPAK Module
Matrix DFE-Diamond Series Installation Guide 3-7
Figure 3-4 XENPAK Module Installation
Removing a XENPAK Module
ToremoveaXENPAKmodulefromthe7KR4290‐02,referbacktoFigure 3‐4andproceedas
follows:
1. Attachtheantistaticwriststrap(refertotheinstructionsintheantistaticwriststrappackage)
beforeremovingtheXENPAKmodule.
2. Removeanynetworkcable(notshown)connectedtotheSCconnectoronthe
XENPAK
module.ToremoveanSCcableconnectorfromtheXENPAKmoduleinterfaceport,carefully
pulltheconnectoroutoftheport.Itmayneedtobeloosenedbygentlymovingitfromsideto
sidetoreleasethelatchingkeys.FormoreinformationaboutanSCcableconnection,referto
“
ConnectingtotheNetwork”onpage 3‐13.
3. TurnthethumbscrewscounterclockwisetoreleasetheXENPAKmodulefromthe7KR4290‐02
frontpanel.
4. GraspthethumbscrewsandpulltheXENPAKmodulestraightoutofthe7KR4290‐02port
slot.
5. BeforestoringorshippingtheXENPAKmodule,insertitintoastatic‐freecontainer.This
completestheremovalprocedure.
1 XENPAK module (10GBASE-LR is shown) 4 Module port slot
2 XENPAK module, Top Side 5 Thumbscrews
3 Edge connector (insertion side)
7KR4290-02
Caution: The XENPAK module and 7KR4290-02 are sensitive to static discharges. Use an
antistatic wrist strap and observe all static precautions during this procedure. Failure to do so can
result in damage to the XENPAK module and 7KR4290-02. Always leave the XENPAK module in
the antistatic bag or an equivalent antistatic container when not installed.
Precaución: Si lo hace, puede dañar el XENPAK ni el módulo 7KR4290-02, puesto que es muy
sensible a las descargas de electricidad estática, al igual que el dispositivo host. Utilice la pulsera
antiestática y tome todas las precauciones necesarias durante este procedimiento. Si no lo hace,
pude dañar el XENPAK ni el módulo 7KR4290-02 o el dispositivo host. Mientras no esté instalado,
mantenga el XENPAK en su bolsa antiestática o en cualquier otro recipiente antiestático.