Installation guide

Module Placement in a Matrix E7 Chassis
2-2 Network Requirements
Module Placement in a Matrix E7 Chassis
Ifyouwanttomix6x1xxx,6x2xxx,6x3xxx,and7H43xxxxseriesmodulesinthesameMatrix E7
chassis,itisnecessarytohaveaDFEbridgingmodulesuchasthe7H438225,7H438249,
7H438349,or7H438549installedandtoalsofollowthemoduleplacementrulesdescribedin
InstallingModuleintoMatrix E7orN7Chassisonpage 310tosuccessfullybridgedatatraffic
tosomeorallmodulesinthechassis.
10BASE-T Network
Whenconnectinga10BASETsegmenttoanyofthefixedfrontpanelportsofthe7GR420230,
ensurethatthenetworkmeetstheEthernetnetworkrequirementsoftheIEEE802.32002standard
for10BASET.RefertotheCablingGuidefordetails.
100BASE-TX Network
Thefixedfrontpanelportsofthe7GR420230provideaconnectionthatsupportsCategory5UTP
cabling.ThedeviceattheotherendofthetwistedpairsegmentmustmeetIEEE802.32002
100BASETXFastEthernetnetworkrequirementsforthedevicestooperateat100 Mbps.Referto
theCabling
Guidefordetails.
1000BASE-T Network
The7GR420230DFEmoduleprovides30portsthatsupport10/100/1000MbpsviaRJ45front
panelconnectors.Theseconnectionssupportcopperwireconnectionsthatcanoperateupto
1000 Mbps.ThedeviceattheotherendofthetwistedpairsegmentmustmeetIEEE802.3200210/
100/1000BASETnetworkrequirements
forthedevicestooperateatGigabitspeed.
1000BASE-SX/LX Network
TheoptionalMiniGBICsinstalledinthe7GR427012portslots1through12,orinthe7GR428019
frontpanelports1through18ortheoptionalNEM,providefiberopticconnectionsoperatingat
1000 Mbps(1 Gbps).OtherMiniGBICsmaysupportdifferenttypesofcablingconnections.The
deviceatthe
otherendofthefiberopticconnectionmustmeetIEEE802.32002GigabitEthernet
requirementsforthedevicestooperateatGigabitspeed.RefertoAppendix Aforfurtherdetails
onMiniGBICspecifications.
Note: If a port is to operate at 100 Mbps, Category 5 cabling must be used. Category 3 cabling
does not meet 100 Mbps specifications. For 10 Mbps operation only, Category 3 or Category 5
cabling can be used. Refer to “100BASE-TX Network” on page 2-2 for information about
100BASE-TX networks and cabling.
Note: The fixed ports of the module support Category 5 UTP cabling with an impedance between
85 and 111 ohms for 100 Mbps operation. The module is capable of operating at 10, 100, or 1000
Mbps and can automatically sense the port speed of the other device and adjust its speed
accordingly.
Note: The fixed ports of the module support Category 5 UTP cabling with an impedance between
85 and 111 ohms for 100 and 1000 Mbps operation.
Front-panel ports 1 through 30 are capable of operating at either 10, 100, or 1000 Mbps. The
module automatically senses the speed of the other device and adjusts its speed accordingly.