Installation guide

Connectivity
1-6 Introduction
Connectivity
7GR4270-12
The7GR427012DFEmodulehas12frontpaneloptionportsthatsupport1000BASEXGigabit
EthernetthroughoptionalMiniGBICs.ForMiniGBICspecifications,refertoAppendix A.
7GR4202-30
The7GR420230DFEmodulehas30,10BASET/100BASETX/1000BASETcompliantports
throughfixedfrontpanelRJ45connectors.
7GR4280-19
The7GR428019DFEmodulehas18,1000BASEXcompliant,SmallFormFactorPluggable(SFP)
fixedfrontpanelportslotsforGigabitEthernetconnectionsusingoptionalMiniGigabitInterface
Cards(MiniGBICs).TheportslotsenableyoutoinstallamixandmatchnumberofSFPstomeet
aneedfor
variousGigabitEthernetconnections.ForMiniGBICspecifications,referto
Appendix A.
Thereisalsoaslotforanoptionalnetworkexpansionmodule(NEM).Refertothe
Enterasys NetworkswebsiteforacurrentlistingoftheavailableNEMs.Specificinstallation
instructionsareshippedwitheachNEM.
7KR4290-02
The 7KR429002 DFEmodulehas 2,10GbpsEthernetportslotsonthefrontpanelthatcan
supportoneortwo10GbpsXENPAKPHYsforhighspeeduplinksfromthechassisDFEEthernet
switchsystem.Withtwo10GbpsPHYsinstalledinthe 7KR429002,ashareduplinkofupto
10 Gbps
canbeprovidedfromtheDFEswitchingsystemtotwonetworkedgeconnectionsfroma
MatrixE7,N7,N5,N3orN1chassistoacoredatacenter.FortheXENPAKPHYspecifications,
refertoAppendix A.
Note: The 7GR4270-12, 7GR4202-30, 7GR4280-19, and 7KR4290-02 DFE modules can be
installed in a Matrix E7, N7, N5, N3 or N1 chassis, but only support FTM2 data backplane
interconnections in the Matrix E7 chassis. Traffic flow from FTM2 to FTM1 can only be
accomplished using a bridging module such as the 7H4382-25, 7H4382-49, 7H4383-49, or
7H4385-49.