Specifications

Logging and Network Management Command Set
Configuring Convergence End Points (CEP) Phone Detection
Matrix E1 Series (1G58x-09 and 1H582-xx) Configuration Guide 11-95
11.2.6.9 set cep detection porthigh
Use this command to set the maximum and minimum ports used for TCP or UDP convergence end
points detection. Once UDP and/or TCP phone detection has been specified using the set cep
detection protocol command as described in Section 11.2.6.8, the protocols will use this port range
for detection matching.
set cep detection detection-id {porthigh | portlow port}
Syntax Description
Command Defaults
None.
Command Type
Switch command.
Command Mode
Read-Write.
Example
This example shows how to set port 65 as the minimum port to be used for convergence end points
detection for CEP group 1
:
NOTE: This command applies only to Siemens and H.323 phone detection. Cisco
detection uses CiscoDP as its discovery method.
detection-id Specifies a CEP discovery group ID. This group must be
created and enabled using the set cep detection command
as described in Section 11.2.6.5. Valid values are 1 -
2147483647.
porthigh |
portlow port
Specifies a maximum or minimum UDP or TCP port to be
used for convergence end points detection.Valid values are
1 - 65535.
Matrix>set cep detection portlow 65