Specifications
Used/Unused Ports report.
C1H124−48 devices do not report the connector type or media type correctly for any installed
mini−GBIC ports in the Used/Unused Ports Report. These ports are also not identified as FRUs in the
FRU Report.
•
C1G124−24 devices may not report the existence of mini−GBIC ports in certain situations.•
V−Series stackable devices with older firmware may report an incorrect number of devices in the
stack when gathering data for the FRU report.
•
6x2xx and 6x3xx devices always report the fan tray as installed in the FRU Report.•
6x1xx/6x2xx/6x3xx and stand−alone 2x2xx devices incorrectly report submodule Description
information in the FRU Report.
•
C2 devices do not report their four SFP GBIC ports in the Used/Unused Ports Report; these
combination RJ45/SFP ports are reported simply as RJ45 ports.
•
2E43−27R devices report an incorrect description for HSIM−F6 submodules in the FRU Report.•
If you have devices that are configured with multiple SNMP contexts in your device tree and you run
a report on those devices, you may see that report results display data for the device configured with
the default context (switch mode) for each device with context. For example, if you target 10.10.20.20
and 10.10.20.20:context, the report may display results for 10.10.20.20 for both devices. Be aware
that this will affect your result totals.
•
NETSIGHT COMPATIBILITY:
Inventory Manager's interoperability and concurrent application capabilities are listed below:
NMS Platform Version No. Support
NetSight Console 2.2 Yes
KNOWN RESTRICTIONS AND LIMITATIONS:
The known restrictions and limitations for this release of NetSight Inventory Manager are listed below.
Solutions for these restrictions and limitations are noted, if available.
Install/Uninstall
Problem 1: (Windows only) An evaluation of your system is not automatically performed during
the installation. If system requirements are not met, the install will take place, but
results will be unpredictable.
Solution: Verify that all Windows platform system requirements are met prior to installing
Inventory Manager.
Problem 2: Solaris only. The installer reports that it is unable to complete the Host Evaluation, and
you cannot proceed with the installation.
Solution: The /tmp directory is probably full. You must exit the installer and reboot the
workstation. You can then restart the installation.
Problem 3: Windows only. After uninstalling a client−only version of Inventory Manager on a
Windows system that has no other NetSight products installed, the NetSight Services