Specifications

select an individual device to see results for just that device. When you change your selection in the
tree, the table is updated with the relevant information.
Device Count, Sufficient Data
The total number of target devices, followed by the number of devices with sufficient data to report
results. A device is counted as having sufficient data if there were two data samples (either two
archives, or one archive and current data) used to obtain report data. This area also reports the number
of devices with FRU components that have been added or removed.
Table
The Removed FRUs table displays FRU data for the selected device group or for the individual devices
contained in the group. The report is generated based on the first and last data samples in the time period
selected. Devices with no data samples or only one data sample, will not be represented in the report results.
IP Address
The IP address of the device reporting the removed FRU component.
FRU Name
The specific name of the FRU component that was removed.
FRU Type
The type of FRU that was removed.
Description
A description of the FRU component that was removed.
FRU Results − All FRU Details
The FRU Details view provides information on the individual FRU components installed on your target
devices. Your selections in the Select FRU Types window determine what components are included in the
report. The report is generated based on the first and last data samples in the time period selected, resulting in
two entries per FRU component (one for each data sample used.) Depending on your selection in the tree, you
can see details for FRUs installed on all the devices in a group or just on an individual device.
NOTES:
Each device is considered a FRU and will have an entry in the table for each
data sample.
Each individual device that resides in a chassis reports the power supplies and
fans for that chassis. So, if your report includes a chassis, there will be an entry
for power supplies and fans reported by each device in the chassis. For
example, if you have four devices in a chassis, each device will report the two
power supplies in the chassis, resulting in eight rows of power supplies in the
table for that one chassis for each data sample. Use the IP Address column in
the report to verify that each device in the chassis is reporting the same
information, and that there are actually only two power supplies in the chassis.
Click the graphic for more information.
Welcome to NetSight Inventory Manager Help
Results Window 164