Installation guide

Commission the MSM to Run Trusted Access Gateway
4-2 Enterasys Sentinel Trusted Access Gateway Setup
3. HighlightYes,andpressEnter.
4. Enterthenewpassword,reenterthepassword,andpressEnter.
TheCONFIGURENETWORKscreenappears.
5. HighlightYestoconfigureyournetwork,andpressEnter.
TheENTERHOSTNAMEscreenappears.
6. EnterthehostnamefortheMSM,thenhighlightOKandpressEnter.
TheSETUPIPADDRESS
FOR“yourhostname”screenappears.
7. Selectfromthefollowing,highlightOK,andpressEnter.
staticIP:usesastaticIPaddresstoconfigureEthernet
DCHP:usesaDHCPservertoconfigureEthernet
loopback:usedtosetupaloopbackconnection(modemornonet)
TheENTERIPADDRESS
FOR“yourhostname”screenappears.
8. EntertheIPAddressoftheMSM,highlightOK,andpressEnter.
TheENTERNETMASKFORLOCALNETWORKscreenappears.
9. EnterthenetmaskoftheMSM,highlightOK,andpressEnter.
TheENTERGATEWAYADDRESSscreenappears.
10. Enterthegatewayaddressforyournetwork, highlight
OK,andpressEnter.
TheUSEANAMESERVERscreenappears.
Note: It is recommended that all passwords be at least eight characters in length.
Note: Static IP is recommended; however, you must evaluate your network environment.
Note: The IP address is automatically configured on the front panel Ethernet port (eth0).
Note: If you do not have a gateway on your network, leave the field blank and press Enter.