Installation guide
Using LANVIEW Diagnostic LEDs
2-16 Installation
Using LANVIEW Diagnostic LEDs
TheMatrixSecurityModuleusesabuilt‐invisualdiagnosticandstatusmonitoring
systemcalledLANVIEW.TheLANVIEWLEDsallowquickobservationofthenetwork
statustoaidindiagnosingnetworkproblems.
Table 2‐1describestheLEDindicationsandprovidesrecommendedactionsas
appropriate.
Note: The terms flashing and solid used in Table 2-1 indicate the following:
• Flashing indicates LED is flashing randomly.
• Solid indicates a steady LED light. No pulsing.
Table 2-1 LANVIEW LEDs
LED Color State Recommended Action
Gigabit Ports Link and Activity LEDs
Lower
LED Link
and
Receive
Off No link. No activity. Port
enabled or disabled.
None.
Green Solid. Link present, port
enabled, no traffic is being
received by the interface.
None.
Amber Flashing. Link present, port
enabled, traffic is being
received by the interface.
None.
Top LED
Transmit
Off Port enabled, but no activity. If it is known that the port should be
active and is not, contact
Enterasys Networks for technical
support.
Green Flashing. Indicates data
transmission activity. Rate of
flashing indicates the data
rate.
None.
Red Flashing. GBIC Fault. Check for defective GBIC device.
10/100 Ethernet Port Link and Activity LEDs
Link Off Off. No activity. Port enabled
or disabled.
None.
Green Solid. Link present, port
enabled,
None.