Installation
Enterasys Matrix Security Module Installation Guide 2-7
3. UsetwoofthesavedcoverplatescrewstofastentheMatrixSecurityModuletothe
DFEmodulefrontpanel,butdonottightenscrewsatthistime.
4. InsertthesavedstandoffthroughtheMatrixSecurityModuletothestandoffonthe
mainboard.Screwinthestandoff,butdonottighten
screwsatthistime.
5. Tightenthetwocoverplatescrewsfirst,thenthestandoff.
6. Reinstallthesafetycoverifapplicable,usingthesevenscrewssavedintheprocedure
“RemovingtheSafetyCover(ifapplicable)”onpage 2‐3.
7. ThiscompletestheMatrixSecurityModuleinstallation.
8. Referto“InstallingOptionalMini‐GBICs”
onpage 2‐12toinstallMini‐GBICsintothe
MatrixSecurityModule.
Installation When Internal Power Not Supplied by the DFE Module
Thisinstallationprocedureappliestothe7S‐NSTAG‐01and7S‐DSNSA7‐01models.
RefertoFigure 2‐4onpage 2‐8,andperformthefollowingsteps:
1. PositiontheMatrixSecurityModule(MSM)soitsfrontpanelisundertheedgeofthe
DFEmodulefrontpanel.
2. CarefullyalignthetwoMatrixSecurity
ModuleconnectorswiththeDFEmainboard
connectors.Thenpressstraightdownovertheconnectors,applyingpressureuntil
theyareproperlyseated.
3. UsetwoofthesavedcoverplatescrewstofastentheMatrixSecurityModuletothe
DFEmodulefrontpanel,butdonottightenscrewsatthistime.
4. Insertthesaved
standoffthroughtheMatrixSecurityModuletothestandoffonthe
mainboard.Screwinthestandoff,butdonottightenscrewsatthistime.
5. Tightenthetwocoverplatescrewsfirst,thenthestandoff.
Warning: The safety cover protects you from exposure to an energy hazard in excess of
240 Volt-Amperes. Never operate the DFE module without the safety cover installed.
Advertencia: La cubierta de seguridad lo protege de exponerlo al riesgo de energía en
exceso de 240 Volt-Amperes. Nunca se debe opererar el modulo de DFE sin la cobertura
de seguridad instalada.
Warnhinweis: Die Sicherheitsabdeckung schützt vor Stromstössen von bis zu 240 VA.
Bitte nehmen Sie niemals die DFE Module ohne die Abdeckung in Betrieb.