Installation guide
Installing the Chassis
Matrix N5 PoE Chassis (7C105-P) Installation Guide 3-9
c. Withthe powersupplyproperlyinsertedintotheopening,carefullyslidethe
supplyforwarduntilitisconnectedtothebackplane.Thefrontpanelshouldbe
flushwiththefaceoftheN5chassis.Ifsignificantresistanceisencounteredbefore
thefrontpanelisflush,removeandreinsertthepowersupply.
Donotforcethe
powersupplyintoplace.
d. Securethepowersupplytothechassisbyusingalargeflatbladescrewdriverto
turnthelargescrewandlock thepowersupplyinplace.
2. Ifyouareinstallingasecondpowersupply,locatethelargescrewontheblankplate
covering
slotPS2andturnthescrewcounterclockwisetoreleaseandremovethe
blankplate(keeptheblankplateincaseyouneedtoremovea7C205‐1andoperate
thechassiswithonlyonepowersupply),andrepeatsteps1.
Figure 3-4 Installing 7C205-1 Power Supply Module
Note: If you need to remove a 7C205-1, refer to “Replacement Procedures” on page 3-17
for instructions.
1 Mandatory power supply installed in slot PS1 4 Slotted screw
2 Power supply handle 5 Blank plate covering slot PS2
3 Sides of PS1 slot
0
50/60Hz
LINE 2:
100-125V~12A
200-240V~6A
50/60Hz
LINE 1:
100-125V~10A
200-240V~5A
POWER FAN
TOP - SLOT 5 BOTTOM - SLOT 1SLOT 4 SLOT 3 SLOT 2
POE 1 POE 3
POE 4POE 2
PS 1
PS 2
CAUTION: THIS UNIT MAY HAVE MORE THAN ONE POWER SUPPLY CORD. DISCONNECT
FOUR (6) POWER SUPPLY CORDS BEFORE SERVICING TO AVOID ELECTRIC SHOCK.
VORSICHT: DIESES GERÄT HAT MEHR ALS EINEN NETZANSSCHLUß. TRENNEN SIE VOR
WARTUNGSARBEITEN DIE 6 NETZANSCHLÜSSE VOM NETZ, UM ELEKTRISCHE SCHLÄGE ZU VERMEIDEN.
100 - 125V ~ 15A
200 - 240V ~ 8A
50/60 Hz
AC INLET 1 AC INLET 3
AC INLET 2 AC INLET 4
100 - 125V ~ 15A
200 - 240V ~ 8A
50/60 Hz
100 - 125V ~ 15A
200 - 240V ~ 8A
50/60 Hz
100 - 125V ~ 15A
200 - 240V ~ 8A
50/60 Hz
À
Â
Á
Ä
Ã