Installation guide

Enterasys Matrix N5 Chassis Modules
1-4 Matrix N5 PoE Chassis (7C105-P) Installation Guide
Enterasys Matrix N5 Chassis Modules
TheN5chassishasfiveslotsforthenewMatrixDFEseriesmoduleswithorwithoutPoE
capability.
Chassis Cooling System
TheN5chassisfeaturesaremovablefourfanassemblythatisaccessiblefromtherearof
thechassis.Thisunitishotswappable,whichallowsittobereplacedwithoutpowering
downthechassis.ALANVIEWLEDlocatedonthefrontofthechassisindicatesthe
operatingstatusofthefan
assembly(normal/fault/notinstalled).RefertoChapter 2fora
fulldescriptionofthefanassemblyLEDstates.
Chassis Power Systems
TheN5chassissupportstwo7C2051powersuppliesthatresideinthelowersectionof
thechassis,inslotslabeledPS1andPS2.Thesecondpowersupplyprovidesredundancy
andloadsharing.ThesepowersuppliesoperateindependentlyfromtheoptionalPoE
powersupplymodulesdescribedinPOEPowerSupply
Systemonpage 15.The
optionalPoEpowersupplymodulesprovidepowertosupportthePoweroverEthernet
featureinPoEcompliantDFEmodulesinstalledinthechassis.
N5 Chassis Power Supply System
The7C2051isa1200Wattpowersupply,whichhasonefrontpanelACinputpower
connector.ThisallowstheconnectionofeachpowersupplytoaseparatelyfusedAC
powersource.Onepowercordisshippedwiththe7C2051.Thetypeofpowercord
shippedwiththeunit
iscountrydependent.
Whentwopowersuppliesareinstalled,eachpowersupplyiscapableofloadsharing50%
(+/‐5%)ofthepowerina7C105Pchassispowerload.Thisnotonlyprovides
redundancy,italsoextendsthelifeofthepowersupplies.Ifonepowersupplyfails,the
otherpowersupplysupportstheentirepowerloadofthechassiswithoutinterruptionto
networktraffic.RefertoInstallationSiteGuidelinesonpage 22forpoweroutlet
requirements.
Note: The N5 chassis supports the DFE (Distributed Forwarding Engine) 7xxxxx or 4xxxxx
series modules, but it does not support the older 6x1xx, 6x2xx, and 6x3xx series of
modules. Do not mix 7xxxxx and 4xxxxx series modules in the same chassis.