Installation guide
Enterasys Matrix N5 Chassis Modules
1-4 Matrix N5 PoE Chassis (7C105-P) Installation Guide
Enterasys Matrix N5 Chassis Modules
TheN5chassishasfiveslotsforthenewMatrixDFEseriesmoduleswithorwithoutPoE
capability.
Chassis Cooling System
TheN5chassisfeaturesaremovablefour‐fanassemblythatisaccessiblefromtherearof
thechassis.Thisunitishotswappable,whichallowsittobereplacedwithoutpowering
downthechassis.ALANVIEWLEDlocatedonthefrontofthechassisindicatesthe
operatingstatusofthefan
assembly(normal/fault/notinstalled).RefertoChapter 2fora
fulldescriptionofthefanassemblyLEDstates.
Chassis Power Systems
TheN5chassissupportstwo7C205‐1powersuppliesthatresideinthelowersectionof
thechassis,inslotslabeledPS1andPS2.Thesecondpowersupplyprovidesredundancy
andloadsharing.ThesepowersuppliesoperateindependentlyfromtheoptionalPoE
powersupplymodulesdescribedin“POEPowerSupply
System”onpage 1‐5.The
optionalPoEpowersupplymodulesprovidepowertosupportthePoweroverEthernet
featureinPoE‐compliantDFEmodulesinstalledinthechassis.
N5 Chassis Power Supply System
The7C205‐1isa1200Wattpowersupply,whichhasonefront‐panelACinputpower
connector.ThisallowstheconnectionofeachpowersupplytoaseparatelyfusedAC
powersource.Onepowercordisshippedwiththe7C205‐1.Thetypeofpowercord
shippedwiththeunit
iscountry‐dependent.
Whentwopowersuppliesareinstalled,eachpowersupplyiscapableofloadsharing50%
(+/‐5%)ofthepowerina7C105‐Pchassispowerload.Thisnotonlyprovides
redundancy,italsoextendsthelifeofthepowersupplies.Ifonepowersupplyfails,the
otherpowersupplysupportstheentirepowerloadofthechassiswithoutinterruptionto
networktraffic.Referto“InstallationSiteGuidelines”onpage 2‐2forpoweroutlet
requirements.
Note: The N5 chassis supports the DFE (Distributed Forwarding Engine) 7xxxxx or 4xxxxx
series modules, but it does not support the older 6x1xx, 6x2xx, and 6x3xx series of
modules. Do not mix 7xxxxx and 4xxxxx series modules in the same chassis.