Installation guide

Using LANVIEW
Troubleshooting 4-3
Table 4-1 LANVIEW LEDs
LED Color State Recommended Action
CPU Red Solid. System is not fully
functional, or the system
is experiencing a fatal
error.
If the LED remains red for several minutes,
the system may have a fatal error. Contact
Enterasys Networks for technical support.
Amber Solid. Power-up testing
in progress.
If the LED remains amber for more than
several minutes, contact Enterasys
Networks for technical support.
Green Solid. System is fully
functional.
None.
Amber
and
Green
Blinking. Device is
booting.
None.
PWR Off No power. Ensure chassis has adequate power.
Amber Solid. Power system
functional.
1. Ensure that the power cords are plugged
in correctly and that there is power at the
two power sources.
2. Contact Enterasys Networks for
technical support.
Green Solid. Power supplies are
functioning and are in the
redundant mode.
None.
Link Off No link.
No activity or port in
standby. Port enabled or
disabled.
None.
Green Solid. Port is linked. None.