Installation guide

Installing Optional GBICs
3-10 Hardware Installation
3.5.1.2 Removing the Side Clip GBIC
To remove the GBIC from the 1G-2GBIC, proceed as follows:
1. Attach the antistatic wrist strap (refer to the instructions in the antistatic wrist strap package)
before removing the GBIC.
2. Remove any cables connected to the GBIC.
3. Refer to Figure 3-4. Locate the locking tabs
on the side of the GBIC .
4. Squeeze both locking tabs
in towards the center of the GBIC and hold, and then pull the
GBIC out of the port.
5. If storing or shipping the GBIC, insert the dust protector into the GBIC to protect the fiber ports.
3.5.2 Locking Bar GBICs
This section describes how to install and remove GBICs that are equipped with a metal locking bar.
Refer to Appendix C for GBIC cable specifications.
CAUTION: Do NOT remove a GBIC from a slot without unlocking the tabs. This can
damage the GBIC.
CAUTION: The GBIC, 1G-2GBIC, and 1H582-xx
are sensitive to static discharges. Use
an antistatic wrist strap and observe all static precautions during this procedure. Failure
to do so could result in damage to the GBIC, 1G-2GBIC, and the host device. Always
leave the GBIC in the antistatic bag in which it was shipped or an equivalent antistatic
container until ready to install it.
.
CAUTION: This section applies only to GBICs equipped with a metal locking bar.
Damage can result to the GBIC and 1G-2GBIC if the directions in this manual are not
followed carefully.
The GBIC, 1G-2GBIC, and 1H582-xx are sensitive to static discharges. Use an
antistatic wrist strap and observe all static precautions during this procedure. Failure to
do so could result in damage to the GBIC, 1G-2GBIC, and the host device. Always leave
the GBIC in the antistatic bag in which it was shipped or an equivalent antistatic
container until ready to install it.