Installation guide
Connecting to COM Port for Local Management
Matrix DFE-Gold Series Modules Installation Guide 3-29
When these parameters are set, the Local Management password screen will display.
Refer to the Matrix DFE-Gold Series Configuration Guide for further information.
Connecting to a Modem
To connect a modem to an Enterasys Networks DFE-Gold module COM port
(Figure 3-20), use a UTP straight-through cable with RJ45 connectors and an RJ45-to-DB25
male adapter, and proceed as follows:
1. Connect the RJ45 connector at one end of the UTP straight-through cable to the COM
port of the DFE-Gold module.
2. Plug the RJ45 connector at the other end of the UTP straight-through cable into the
RJ45-to-DB25 modem adapter.
3. Connect the RJ45-to-DB25 adapter to the communications port on the modem.
4. Turn on the modem.
Figure 3-19 Connecting a VT Series Terminal
1 UTP straight-through cable with RJ45 connectors 3 RJ45-to-DB25 VT adapter
2 RJ45 COM port 4 VT series terminal
1X
RESET
COM
CPU
MGMT
GROUP
SELECT
GROUP
1
1
4H4282-49
FAST ENET
Á
ÂÀÃ