Installation guide

Installing an Optional Mini-GBIC
Matrix DFE-Gold Series Modules Installation Guide 3-7
Removing the Mini-GBIC
To remove a Mini-GBIC from a port slot, refer back to Figure 3-3 and Figure 3-4, and
proceed as follows:
1. Attach the antistatic wrist strap (refer to the instructions in the antistatic wrist strap
package) before removing the Mini-GBIC.
2. Remove the cables connected to the Mini-GBIC.
3. Locate the release tab under the front end of the Mini-GBIC. For the type of
Mini-GBIC shown in Figure 3-3, push in on the release tab as far as it will go to release
the Mini-GBIC from the port slot. For the type of Mini-GBIC shown in Figure 3-4, pull
out on the release tab to release the Mini-GBIC from the port slot.
Figure 3-4 Mini-GBIC with LC Connector
1 Mini-GBIC (MGBIC-LC01 or MGBIC-LC09) 4 Port slot
2 Mini-GBIC, top side 5 Mini-GBIC, protective dust cover
3 7-Pin edge connector (insertion side) 6 Release tab
Caution: Do NOT remove a Mini-GBIC from a slot without releasing the locking tab
located under the front bottom end of the Mini-GBIC
. This can damage the Mini-GBIC.
This is also true of the RJ45 Mini-GBICs with a wire handle. The handle must be pulled
down toward the bottom of the Mini-GBIC to release it.
The Mini-GBIC and its host device are sensitive to static discharges. Use an antistatic
wrist strap and observe all static precautions during this procedure. Failure to do so could
result in damaging the Mini-GBIC or host device. Always leave the Mini-GBIC in the
antistatic bag or an equivalent antistatic container when not installed.