Installation guide

Installing an Optional Mini-GBIC
Matrix DFE-Gold Series Modules Installation Guide 3-5
Installing an Optional Mini-GBIC
This section describes how to install a Mini-GBIC in an optional 7G-6MGBIC.
To prepare and install a Mini-GBIC, proceed as follows:
Preparation
Before installing the Mini-GBIC, proceed as follows:
1. Attach the antistatic wrist strap (refer to the instructions in the antistatic wrist strap
package) before removing the Mini-GBIC from the antistatic packaging.
2. Remove the Mini-GBIC from the packaging.
3. If there is a protective dust cover (see 5 in Figure 3-3 or Figure 3-4) on the Mini-GBIC
port, do not remove it at this time.
Installation
To install a Mini-GBIC with an MT-RJ connection, refer to Figure 3-3, or for a Mini-GBIC
with an LC connection, refer to Figure 3-4, and proceed as follows:
Warning: Fiber-optic Mini-GBICs use Class 1 lasers. Do not use optical instruments to
view the laser output. The use of optical instruments to view laser output increases eye
hazard. When viewing the output optical port, power must be removed from the network
adapter.
Advertencia: Los Mini-GBICS de fibra optica usan lasers de clase 1.No se debe usar
instrumentos opticos para ver la potencia laser El uso de los instrumentos opticos para ver
la potencia laser incrementa el riesgo a los ojos.Cuando vean el puerto de la potencia
optica , la corriente debe ser removida del adaptador de la red.
Warnhinweis: Mini-GBICs mit Fiber-Optik Technologie benutzen Laser der Klasse 1.
Benutzen sie keinesfalls optische Hilfsmittel, um die Funktion des Lasers zu überprüfen.
Solche Hilfsmittel erhöhen die Gefahr von Sehschäden. Wenn sie den optischen Port
überprüfen möchten stellen Sie sicher, dass die Komponente von der
Spannungsversorgung getrennt ist.
Caution: Carefully follow the instructions in this manual to avoid damaging the Mini-GBIC,
7G-6MGBIC, and DFE-Gold module.
The Mini-GBIC, 7G-6MGBIC, and DFE-Gold module are sensitive to static discharges.
Use an antistatic wrist strap and observe all static precautions during this procedure.
Failure to do so could result in damage to the Mini-GBIC, 7G-6MGBIC, and
DFE-Gold module. Always leave the Mini-GBIC in the antistatic bag or an equivalent
antistatic container when not installed.
Note: If the Mini-GBIC is one with an RJ45 connector (not shown), the installation
procedure is the same as described below. However, the Mini-GBIC has a wire handle to
release it.