Installing Optional Ethernet Interface Module
Matrix DFE-Gold Series Modules Installation Guide 3-3
Removing the Coverplate
Refer to Figure 3-1 and proceed as follows:
1. Attach the antistatic wrist strap (refer to the instructions on the antistatic wrist strap
package).
2. Place the DFE-Gold module on an antistatic pad on a sturdy flat surface.
3. Remove the two screws fastening the coverplate to the DFE-Gold module front panel.
Save the two screws for installing the optional interface module.
Installing the 7G-6MGBIC
Refer to Figure 3-2 and proceed as follows:
1. Remove and save the screw from the screw hole in the main board.
2. Locate the standoff shipped with the interface module and screw it into the same
screw hole in the main board.
3. Position the interface module so its front panel is under the edge of the
DFE-Gold module front panel.
4. Carefully align the two interface module connectors with the main board connectors.
Then press straight down over the two interface module connectors, applying
pressure until they are properly seated.
Figure 3-1 Removing the Coverplate
1 DFE-Gold module (4H4282-49 shown as example) 3 Coverplate
2 Coverplate screws (2) 4 DFE Module front panel
4H4282-49
F
AST ENET
DFE