Installation guide
Connecting Power to the Switch
Enterasys G-Series Hardware Installation Guide 2-13
WhenyouinstallanIOMintoaslotthatpreviouslyhadanIOMinstalled,then:
•IftheIOMbeinginstalledisthesametypeasthepreviousIOM,theoldconfigurationwillbe
appliedtotheportsonthenewIOM.
•IftheIOMbeinginstalledisnotthesametypeas
thepreviousIOM,thedefaultconfiguration
willbeappliedtotheports.
Formoreinformationaboutthedefaultconfiguration,seetheEnterasysG‐SeriesCLIReference
Guide.
Removing an IOM
ToremoveaninstalledIOM:
1. DisconnectanycablingfromtheIOM.
2. PressandholdthePOWEROFFbuttoncorrespondingtotheslotfromwhichyouare
removingtheIOMforfiveseconds.Theslot’sstatusLEDflashesgreen.RefertoFigure 3‐1on
page 3‐2forthelocationofthePOWEROFF
button.
3. Whentheslot’sstatusLEDturnsamber,itissafetoremovetheIOM.LoosentheIOM’s two
captivescrewsandgentlyslidetheIOMoutoftheslotusingtheIOM’shandle.Formore
information,referto“IOMStatusLEDs”onpage 3‐3
.
4. Replacethecoverplatetotheslotbytighteningthecoverplate’scaptivescrews.
TheportsassociatedwiththeremovedIOMcontinuetoshowupwhendisplayingportstatus,
indicatingaconfigurationexistsfortheseports,buttheyarein“detached”state.
Connecting Power to the Switch
Youcaninstallasingleprimarysourceofpowerorprovidetwosourcesofpowerforredundancy,
asdescribedinthefollowingsections.Examplesbelowillustrateconnectingtwopowersources
andassumetwopowersupplymoduleshavealreadybeeninstalledasdescribedpreviouslyin
“InstallingaPowerSupply”onpage 2
‐8.
ToconnecttheG‐Seriesswitchtooneortwopowersources,proceedasfollows:
1. PluganappropriatepowercordintoeachswitchACpowerreceptacleasfollows:
•G3‐PWR‐POEacceptsanIEC320C19(20A)powercord.
•G3‐PWRacceptsanIEC320C13(15A)powercord.
Caution: Do not attempt to remove an IOM from the G-Series switch when power is on to the
switch without performing the following procedure.
Precaución: No intente retirar el módulo IOM del switch G Series si éste está encendido. Antes de
hacerlo, debe realizar el siguiente procedimiento.
Caution: Use caution when removing an IOM on which you have optional PoE installed to avoid
damaging the PoE module.
Precaución: Tenga cuidado al retirar un IOM que tenga un módulo PoE instalado, ya que éste
puede dañarse.
Note: The two power supplies in the G-Series have automatic voltage sensing that allows
connection to power sources ranging from 100–125 Vac, 12 A or 200–240 Vac, 7A,
50/60
Hz.