Installation guide

Mounting the Switch
2-4 Installation
Placing the Switch on a Flat Surface
Wheninstallingtheswitchonaflatsurface,theinstallationoftherubberfeetisrecommendedto
preventtheswitchfromsliding.Also,thesurfacemustbeabletosupport15.5kg(35lbs)ofstatic
weight.
Toinstalltherubberfeet,proceedasfollows:
1. Placetheswitchupsidedownon
asturdyflatsurface.
2. Removethefourrubberfeetfromtheshippingbox.
3. Removetheprotectivestripfromthebackofonerubberfootandpositionitononeofthe
cornersonthebottomoftheswitch.Pressfirmlyintoplace.Repeatthisproceduretoinstall
theremainingrubberfeetin
theothercorners.
4. Afterinstallingtherubberfeet,returntheswitchtoitsuprightposition.
5. Placetheswitchinitsfinallocation.
Installing the Switch into a Rack
TheGSeriesEthernetswitchcanbemountedinastandardEIA310Dcompliant48.26centimeter
(19inch)equipmentrack.Tomounttheswitchintoarack,youmustfirstinstalltherackmount
kit,whichconsistsoftwobrackets.Youmustprovidethemountinghardwaretoattachtheswitch
bracketstotherails.
Toinstalltherackmountkitandtheninstalltheswitchintotherack:
1. Placetheswitchonasturdyflatsurface.
2. Installtheleftandrightmountingbracketsprovidedintherackmountkittothesidesofthe
switchusingthescrewsprovidedasshown
inFigure 21.
Caution: To ensure proper ventilation and prevent overheating, leave a minimum
clearance space of 3.81cm (1.5 in.) at the left, right, and rear of the G-Series.
Do not connect the G-Series to the AC power source until instructed to do so later in the
installation process.
Precaución: Para asegurar una buena ventilación y evitar que el sistema se
sobrecaliente, deje un espacio mínimo de 3.81cm (1.5 pulgadas) con respecto a los lados
y a la parte posterior del aparato.
No conecte el dipositivo a la fuente primaria hasta que no se le indique.
Caution: Before installing the screws as described in this installation procedure, refer to “Torque
Values” on page A-6.
Precaución: Antes de retirar los tornillos, tal como se describe en las instrucciones de instalación,
consulte “Torque Values” on page A-6.
Note: The G-Series Ethernet switch (with rubber feet installed) will exceed the 2U high Richmond
standard and will not comply with the requirements for mounting in a 19-inch (48.26-centimeter)
rack. Remove the rubber feet, if installed, before installing the switch into a rack.